Add to Cart
Thermal Insulation Rubber Maximum Service Temperature Test Machine ASTM C411-82 Standards
Scope of application:
It is applicable to the evaluation of the maximum service
temperature of thermal insulation products such as loose filled
thermal insulation materials, felt, blanket, block, plate and
prefabricated thermal insulation pipe shell.
Standard:
ASTM C411-82
ASTM C447-85
ASTM C411-82
ASTM C447-85
ISO 8142: 1990 catalogue A.
Main technical parameters:
1. Heating plate: made of SUS304 stainless steel, test area 900 *
450mm, protective layer around, width 80mm. On the lower surface of
the heating plate, at least five thermocouples shall be used to
measure the surface temperature, four of which shall be fixed on
the diagonal of the heating area of the heating plate, and the
distance from each corner shall be 150 mm. The fifth thermocouple
shall be placed in the center of the heating plate. The temperature
measured at any point shall not be lower than the required
temperature, and the difference shall be+5% or+15 ℃, whichever is
smaller.
2. Heating pipe: made of SUS304 stainless steel, with a length of
2M and nominal diameters of 88mm, 108mm and 133mm respectively. The
three heating pipes are arranged side by side, and the
prefabricated insulation pipe shell can be tested separately. The
end of the heating pipe shall be provided with a protective section
and an auxiliary heater no less than 75mm long to prevent excessive
heat loss at the end of the test piece. A thermocouple shall be
installed every 0.3m of the heating pipe to measure the surface
temperature of the heating pipe. The thermocouples are arranged
around the heating tubes in a spiral shape at 90 ° intervals. The
temperature measured at any point shall not be lower than the
required temperature, with a difference of+5% or+15 ℃ (whichever is
smaller).
3. Temperature measurement system: thermocouple wire with diameter
of 5.0mm
4. Measuring temperature: 0-500, 0-900, 0-1250 ℃ (optional);
PLC+module is used to collect temperature.
5. Control part: PLC module is adopted, and microcomputer control
is used to display the temperature curve of hot surface in real
time and output the report.
6. Temperature acquisition: once every 2min and displayed by curve;
7. Response time of thermocouple:<0.5s
8. Temperature error: ± 0.5 ℃
9. Timing error: 1s/h
10. Computer: one set of computer (at least meeting the following
requirements: first-line brand computer; CPU: INTEL I5-III or
above; memory: 4G or above; hard disk: 500G or above; with serial
port: controlling instrument operation; display: LED liquid crystal
display above 20 inches, 1600 * 900 resolution or above; windows xp
system), A printer. A set of test software.
11. Equipped with a flat ruler and a feeler gauge: measure the
warpage.
12. Two sample tanks are provided
13, Product features: CNC machine tools are used for processing and
forming, and the arc shape is beautiful and generous. It has the
characteristics of beautiful, rust proof and anti-corrosion. Other
parts are made of 45 # steel with thickened plated/SUS304 stainless
steel surface.
Test furnace size | L2245 × W1500 × H1600(mm) |
Control box size | L500 × W500 × H1200 (mm) |
Heating rate | 5 ℃/min or 3 ℃/min can be set |