48Hz-62Hz Power Frequency High Voltage Tracking Index Flammability Test Machine For Electrical Insulation Iec60598-2007

Technical Description:


The high-voltage leakage tracking tester is suitable for conducting electric tracking and erosion resistance tests on electrical and electronic products, household appliances and their materials. It is simulated at the power frequency (48Hz-62Hz) with liquid pollutants and inclined samples. The measurement of resistance to electrical tracking and erosion assesses the resistance to electrical tracking and erosion of electrical insulation materials used under severe environmental conditions. This machine is designed and manufactured in strict accordance with GB / T6553-2014 and IEC60587-2007.


Standard:


IEC60587-2007, ASTM D2303

Parameters:


1. Electrode: 0.5mm thick Material: stainless steel;
2. The distance between the upper and lower electrodes: 50.0mm ± 0.1;
3. Test voltage: 100V-6000V stepless adjustable;
4. Automatic voltage regulator: Output: 0 ~ 250V automatic electronic voltage regulator, capacity 6KVA;
5. Test transformer: capacity 6KVA, maximum output voltage AC6000V (or DC6000V optional);
6. High-precision voltage stabilizer: output AC220V power 6000W, accuracy ± 1%; 7, cut off the voltage output when the loop current is 60mA
8. Test time: 6 hours; 9. Dropping accuracy: 0.5%; 10. Voltage stability: ± 1%;
11. Tracking judgment: According to the standard GB / T6553-2014 / 4.1.2, apply voltage (2.5kV, 3.5kV and 4.5kV) to the sample, and drop the contaminated liquid at a certain flow rate, at 60mA The following current continues for 6H, but the current is passed;
12, dripping device: using precision peristaltic pump, flow rate of 0.00185 ~ 1 ml / minute, working speed of 0.1 ~ 10 rpm / minute, flow accuracy error: <0.5%;
13. Output voltage: AC / DC (switchable)
14, the number of experimental groups: five groups (a pump controls a group of drips during the test, the test process does not affect each other, not a pump commonly seen in the market to control five groups)
15. Control device: Adopt high-end PLC + Taiwan Weilun touch screen control, precise control, simple operation, completely humanized design, automatic report generation after the test, panel thermal printer can print the test results in a timely manner;
15. Studio volume: 900L * 650W * 950H (mm); volume is 0.56m3.
16. Chassis: Electrostatic spray coating on the surface of iron plate (SUS304 stainless steel brushed surface is optional);
17. The septic tank is made of 316 stainless steel, and a closed device is installed.
18. Overall dimensions of the instrument: 1300L * 700W * 1800H (mm)
Box≥ 0.5 cubic meters
Drop size44 to 50 drops / cm3
Power supplyAC 220V, 50Hz
Electrical load100 ~ 6000V adjustable
Drip height30mm ~ 40mm adjustable
Electrode Pressure1.00N±0.05N
Flow range0.00185 to 2 ml / min
Working speed0.1 to 15 rev / min