ASTM E1354 Fire Test Heat Release , Smoke Production And Mass Loss Rate Flammability Testing Equipment

Brand Name:Daxian
Certification:ISO EN 5660-1、 ASTM E1354、BS 476:PART 15、GB/T 16172-2007
Model Number:DX8348
Minimum Order Quantity:one set
Delivery Time:15work days
Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No.168 Zhen'an West Road Changlian Industry Mansion Xiabian Community Dongguan China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

Reaction-to-fire Tests: Heat Release, Smoke Production and Mass Loss Rate Flammability Testing Equipment

Application:
This equipment is used for assessing the heat release rate and dynamic smoke production rate of specimens exposed in the horizontal orientation to controlled levels of irradiance with an external igniter.

Equipment standard:
- BS 476:PART 15
- GB/T 16172-2007

- ISO EN 5660-1
- ASTM E1354



Working conditions:

the working environment temperature0 ºC ~ 50 ºC
Humidity of working environment<80%
Power supply380V ± 50%,50Hz ± 2%


Cone-shaped radiant electrical heater:
- capable of delivering 5000W at the operating voltage of 230V.
- irradiance of the surface of the specimen shall maintain in a preset level of up to 75 kW/m2.
- three K-type thermocouples for controlling the average temperature of heater ( ±10˚C )

Removable radiation shield:
to protect the specimen from the irradiance prior to the start of a test.

Weighting device:
- a resolution of 0.1 g and an accuracy of ± 0.3 g.
- a 10% to 90% response time of 4s or less.
- Measuring the mass of specimen of at least 500 g.

Specimen holder:
- a square pan with an opening of (106 ± 1) mm at the top, and a depth of (25 ±1)mm
- a ceramic fibre blanket of density 65 kg/m3 by 13 mm thickness at the bottom.

Ignition circuit and timer:
- a spark plug powered from a 10kV transformer or spark igniter.
- recording elapsed time to the nearest second and an accurate to within 1 s in one hour.

Oxygen analyser:
- paramagnetic type, with a range of 0% oxygen to 25% oxygen.
- a drift of not more than 50 µl/l of oxygen over a period of 30 minutes.
- a 10% to 90% of full-scale response time of less than 12 s.

Smoke obscuration measuring system
- a helium-neon laser (between 0.5 mW and 2 mW, polarized), silicon photodiodes and reference detector.



Website: https://www.firetesting-equipment.com/

China ASTM E1354 Fire Test Heat Release , Smoke Production And Mass Loss Rate Flammability Testing Equipment supplier

ASTM E1354 Fire Test Heat Release , Smoke Production And Mass Loss Rate Flammability Testing Equipment

Inquiry Cart 0