IEC60754 Wire and Cable Emission of Halogens HFFR Testing Equipment

Brand Name:DAXIAN
Certification:CE, SGS, ISO
Model Number:DX8332
Minimum Order Quantity:1 set
Delivery Time:30 days after order confirmed
Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No.168 Zhen'an West Road Changlian Industry Mansion Xiabian Community Dongguan China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

IEC60754 Wire and Cable Emission of Halogens HFFR Testing Equipment


Meets the standards:

It conforms to the standards of GB/T17650.1-1998, GB/T17650.2-1998 and IEC60754‐1:1994, IEC60754‐2:1991; it also satisfies the GB/T19666‐2005 “General Rules for Flame Retardant and Fire-resistant Wire and Cable”. Table 6 regulations and GA306.1-2007 Section 6.3.4, GA306.2-2007 Section 6.3.4, UL2556-2007 Sections 9.10 and 9.11 requirements.

Scope of application: It is applicable to the determination of the total amount of halogen acid gas in low-halogen and halogen-free flame-retardant cables and the determination of the acidity of gases by measuring PH value and conductivity.


Equipment composition:

First, tube furnace: The effective length of the heating chamber and the diameter of 600 × ф 42mm, equipped with an adjustable electrical heating system. Heating power: 220V /10KW

Second, the combustion tube:

1, material: refractory tube made of silica, corrosion-resistant gas.

2. Specification: The inner diameter is 40mm, the length extending from the inlet side of the tube furnace is 60~200mm, and the length extending from the outlet side is 60~100mm, leaving a space for thermal expansion.

Third, the burning boat:

1, Material: fused quartz tube.

2, specifications: length 100mm, width 25mm, depth 10mm.

3, the combustion boat into the way: the use of bar magnets and platinum wire stroke method.

Fourth, the gas collection: the use of two bottles: one with a magnetic stirrer, and holds 220mL of sodium hydroxide solution.

V. Gas Supply System:

1,Air flow meter: 20mL~200mL adjustable

2. Compressor (provided by your company)

Sixth, sampling: 500mg~1000mg

Seven, the determination of halogen acid content:

1. Analytical balance: the accuracy is 0.1mg

2. Digital PH meter: accuracy is 0.02PH

3, conductivity meter: Measuring range: (0 ~ 1 × 105) μS/cm

China IEC60754 Wire and Cable Emission of Halogens HFFR Testing Equipment supplier

IEC60754 Wire and Cable Emission of Halogens HFFR Testing Equipment