KE7302 Three Phase Portable Meter Tester

Accuracy : 0.2, Test method: clamp CT and terminal input. KE7302 is used to calibrate three phase, single phase, active or reactive energy meter, and also it can be used as voltage, current and power meter to measure AC parameter of three phase power grid.

Advantages:

  1. Measure all kinds of meter, include single phase (1P2W) meter, three phase three wire meter (3P3W), three phase four wire meter (3P4W) etc
  2. Measure the current with clamp CT and terminal two mode.
  3. Measure Vrms, Irms, phase angle, active power, reactive power, apparent power of three phase or single phase
  4. Measure total active power and total reactive power of three phase;
  5. Measure phase angle
  6. Measure frequency of power grid
  7. Display vector diagram
  8. Display waveform of voltage and current
  9. Analyze and display 2nd – 51st harmonic of voltage and current at real time
  10. Energy accumulating test (Dial test)
  11. Auto-check external wiring correct or not
  12. Test ratio of current transformer in low voltage circuit
  13. Wiring emulation, can simulate all kind of wirings on site without input voltage and current
  14. Realtime clock, accurate record testing time
  15. Store, browse and transfer measured data
  16. Real-time measured data by PC, and download calibration parameter
  17. Two kinds of power supply way: external AC power and voltage test lead power


Technical parameters:

KE7302
Voltage measurement
Voltage range3 x (0V – 480V)
Accuracy±0.1%
Harmonics2nd- 51st
Current measurement
Current rangeTerminal input0.1A – 10A
Clamp input5A, 20A, 100A, 500A, 1000A, 2000A, 3000A
AccuracyTerminal input±0.2%
Clamp input±0.2%(5A), ±0.5% (others)
Harmonics2nd- 51st
Power measurement
Active powerTerminal input±0.2%
Clamp input±0.2%(5A), ±0.5% (others)
Reactive powerTerminal input±0.2%
Clamp input±0.2%(5A), ±0.5%(others)
Energy measurement
Active energyTerminal input±0.2%
Clamp input±0.2%(5A), ±0.5%(others)
Reactive energyTerminal input±0.2%
Clamp input±0.2%(5A), ±0.5%(others)
Phase measurement
Phase range0 -- 360°
Accuracy±0.1°
Frequency measurement
Frequency range45Hz – 65Hz
Accuracy±0.05Hz
Pulse output
Low frequency output(CL)3600imp / kWh
Ppulse input
Input channel1
Input frequencyMax. 100Hz
Others
Power supply

Build-in rechargeable battery,

external power supply,

powered from the tested terminal

Dimensions214mm×150mm×50mm
Weight1.3kg



Front panel


1 — LCD display
2 —Number key
3 —Function key

On the front panel, there is a LCD screen and 18 keys. Keys are consist of number key and function key. All the operation can be done via these keys.


Back panel

1 —Nameplate
2 —Air inlet
3 —Air outlet


China Class 0.2 Portable Energy Meter , Field Electric Meter Calibration Equipment supplier