Three Phase 3CT MV 17.5kV Pole Mounted Metering Transformer

Three Phase 3CT MV 17.5kV Pole Mounted Metering Transformer

Brand Name:Chuangyin
Certification:KEMA/type test report
Model Number:OMB-17.5F (JLSZXW3-17.5F)
Minimum Order Quantity:1 pc
Delivery Time:5-10 workdays
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 1st Floor, B Block, Jiada R&D Building, Nanshan, Shenzhen, China
Supplier`s last login times: within 13 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

OMD-17.5,OMD-24
Overhead pole mounted primary metering unit


This type of metering box is an outdoor dry-type three-phase primary metering unit. The medium-voltage metering transformer is assembled by 3 single-phase combined transformers. Each single-phase combined transformer contains 1 set of CT coil and 1 set of VT coil, Cyclic epoxy resin (CEP) vacuum casting solid encapsulation, with excellent insulation performance and hydrophobicity, the surface is resistant to acid and alkali corrosion, contamination, and UV. It is suitable for outdoor overhead line installation and connection to public power systems. The metering box has connected the secondary lead of the transformer to the junction box of the centralized terminal. The sealing design of the junction box has an output port to connect with the meter box, which is quick to install. It is suitable for the equipment in the urban and rural power distribution network with the maximal voltage not more than 17.5kV for electric energy metering, current and voltage measurement.


1.General parameters:

No.itemunitsspecification
1

Highest voltage for
equipment Um (r.m.s.)


kV17.5
2Rated frequency (fR)Hz50, 60 or 50/60
3

Rated lightning impulse
withstand voltage (peak)


kV95 kV,110 kV
4

Rated power-frequency
withstand voltage on primary


kV38
5

Rated power-frequency
withstand voltage on secondary


kV3
6Number of CTs and VTspcs3VT+3CT
7Standard/

IEC 61869-1:2007, IEC 61869-2:2012

IEC 61869-3:2011,IEC 61869-4:2013

IEEE (ANSI) C57.12-2016

2.Function and application


Overhead pole mounted primary metering unit complies with the latest applicable industrial standards and local and or national electrical code (such as IEC, IEEE (ANSI), CAN, GOST, CEF). It is used for three-phase overhead power grid energy measurement management and distribution network automation management system, the primary side measurement is more accurate, and the power loss of the line can be effectively measured so as to reduce losses.


3.Main features


3.1The medium voltage transformer of the metering unit is composed of 3 single-phase combined transformers, which saves installation space and can be installed directly on the pole outdoors, which is convenient and quick;


3.2The junction box of the metering unit is installed with a test terminal block and the lead wire connected to the transformer, and the junction box door lock seal structure is with anti-electricity stealing design. The metering box can also be equipped with an electric meter box on the pole;


3.3The box is made of corrosion-resistant stainless steel or equivalent performance low-carbon steel with protective coating. The sealing design is weatherproof, acid and alkali corrosion resistant, and UV resistant;


3.4The medium voltage transformer is insulated with epoxy resin solid encapsulation and has excellent dielectric and mechanical performance. It is oil-free, gas-free and maintenance-free, meeting the requirements of safe operation and environmental protection.


3.5The CT of the medium voltage combined transformer can be configured according to double transformation ratios, and the VT is equipped with anti-short circuit and overload protection devices as required to avoid burning and explosion caused by VT short circuit and overload.


3.6The primary connection adopts copper contact bar and terminal clamp and can be equipped with terminal connectors with corresponding area as per user’s requirement. Lightning arrester can be selected as required.


4.Technical parameters.


Current transformer specifications

NoItemSpecification
Rated primary current5A up to 800A
Rated secondary current5A or 1A
Rated Continuous Thermal Current120%,125%,150%,200%,etc.
Rated Short time current (Ith) (thermal 1 second)80xIpr,100xIpr
Rated Dynamic Current (Idyn)2.5xIth
Rated Output(VA)5,10,12.5,15,20
Accuracy Class0.2S,0.2,0.5S,0.5,1 Metering
Instrument Security Factor (FS)5,10,20
Applicable StandardIEC: 61869-1&2


Voltage transformer specifications


NoItemSpecification
Rated primary voltage(V)13200/√3,13800/√3, 15000/√3,7200,8400
Rated secondary voltage(V)100/√3,110/√3, 115/√3, 120/√3, 110,115,120
Rated Voltage Factor

1.2/Continuous

1.5/30s,1.9/30s,1.9/8h

1.5/30s,1.9/30s,1.9/8h

Standard connectionY-Y connection
Rated Output(VA)15,20,25,30,50,75
Accuracy Class0.2,0.5,1,3 Metering
Thermal burden(VA)500
Applicable StandardIEC: 61869-1&3

If the parameter requested exceeds the range of the above table, it can be determined after negotiation with our company.


5.Dimensions and wiring schematic diagram.


Selective meter box 1 (IEC) can be manufactured as per required sizes


Selective meter box 2 (ANSI) can be manufactured as per required sizes



6.Special instructions.
The company can design and manufacture specially according to the special requirements of customers.


China Three Phase 3CT MV 17.5kV Pole Mounted Metering Transformer supplier