24kv Indoor Single-Phrase Epoxy Resin Current Transformer for Protection

Brand Name:Chuangyin
Certification:Kema,CE,SGS,TUV
Model Number:LZZBJ9-24-180/b/2
Minimum Order Quantity:1set
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Place of Origin:Shenzhen
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 1st Floor, B Block, Jiada R&D Building, Nanshan, Shenzhen, China
Supplier`s last login times: within 13 hours
Product Details Company Profile
Product Details


24kv Indoor Single-Phrase Epoxy Resin Current Transformer for Protection



1.Product Introduction:


LZZBJ9-24-180b-2 LZZBJ9-24-180b-4 current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omni-directional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50Hz or 60Hz and highest voltage for equipment 17.5(24) kv


2. Technical Data:



Main technical parameter
1. Rated insulation voltage: 24/50/125kV etc.
2. Rated frequency: 50/60hz
3. Installation Site: Indoor
4. Standards: IEC60044-1(IEC61869-1&2)


3. Specification:
Rated current ratio(A)Secondary accuracy classes combination

Rated output

(VA)

Measuring current’s instrument security factorProtective current’s accuracy limit factorRated short-time thermal current (kA/S)Rated dynamic current ( kA)
MeasuringProtective
0.2(S)0.510P
20-200/5

0.2(S)/0.2(S)

0.2(S)/0.5

0.2(S)/10P

0.5/10P

10

15

1515

5

(10)

10

15

150I1n375I1n
300/531.580
400/531.580
500/540100
600/550125
800/52063125
1000/580160
1250/580160

Three secondary single ratio

Rated current ratio(A)Secondary accuracy classes combination

Rated output

(VA)

Measuring current’s instrument security factor(FS)Protective current’s accuracy limit factor(ALF)Rated short-time thermal current (kA/S)Rated dynamic current ( kA)
MeasuringProtective
0.2(S)0.510P
15-300/5

0.2S/0.5/10P

0.2/0.5/10P

0.5/0.5/10P

0.2S/10P/10P

0.2/10P/10P

0.5/10P/10P

1515

15


20

5

(10)

10

15


20

150I1n375I1n

400/5~

600/5

50105

800/5~

1000/5

63130
1200/580160
1500/580160
2000/5100200
2500/5125200
Three secondary double ratio
Rated current ratio(A)Secondary accuracy classes combination

Rated output

(VA)

FSALFRated short-time thermal current (kA/S)Rated dynamic current ( kA)
MeasuringProtective
0.2(S)0.510P

15-30/5

20-40/5

…..

500-1000/5

0.2S/0.5/10P

0.2/0.5/10P

0.5/0.5/10P

0.2S/10P/10P

0.2/10P/10P

0.5/10P/10P

1515

10


15

5

(10)

10


15

100I1n250I1n
600-1200/550105
750-1500/563130
800-1600/580160
1000-2000/580160
1250-2500/5100200
4. Outline Drawing:
5.Photos:
China 24kv Indoor Single-Phrase Epoxy Resin Current Transformer for Protection supplier

24kv Indoor Single-Phrase Epoxy Resin Current Transformer for Protection

Inquiry Cart 0