China Tencan 1900*1200*930mm Double Sides with 8 Glove Ports Inert Gas Glove Box


Brief Introduction


The Purification System Glove Box represents a crucial laboratory apparatus. It operates by filling the interior of the box with a high-purity inert gas, while simultaneously and continuously filtering out active substances from the box. This device is alternatively known as the “vacuum glove box with water and oxygen removal” or the “inert gas purification glove box”. Its principal functions encompass the removal of water content, oxygen content, and other organic gases. Owing to these capabilities, it is extensively employed to create a high-purity environment that is devoid of water, oxygen, and dust, thereby meeting the stringent requirements of a wide range of scientific and industrial applications. Whether it’s in cutting-edge materials research, sensitive chemical synthesis, or precision electronics manufacturing, this glove box provides the necessary controlled conditions to ensure reliable results and product quality.


Working principle


The box and purification system are joined together to form a securely sealed working space. By continuously filling the box with inert gas or nitrogen, the active substances inside are continuously removed in a cyclic process, guaranteeing that the box interior consistently maintains a high degree of cleanliness and a high-purity inert gas environment (with a water content not exceeding 1 ppm and an oxygen content not exceeding 1 ppm).


Structure Principle


The Purification System Glove Box comprises two key elements: the main box body and a transition chamber, both of which can be customized to suit our clients' specific requirements.

The main box body boasts two or more glove operation interfaces positioned either at the front or back, facilitating concurrent operation by one or multiple individuals and thereby enhancing the efficiency of the glove box. Moreover, observation windows located on the front or back offer a clear sight line into the operations occurring within. Air suction and charging nozzles are integrated into the valves of the transition chamber, enabling the adjustment of air as required. Additionally, the main box body is furnished with a valve and nozzle system designed to maintain a stable air pressure inside the box whenever necessary.

The transition chamber functions as an intermediary space between the main box body and the external environment. It is comprised of two sealing doors, two valves, and a chamber body. Both sealing doors effectively seal off the interior of the main box body from the outside, enabling the seamless transfer of items in and out of the box without the necessity for repetitive evacuations and inflations, as the box body remains airtight.


Applications


Applies to making pure environment with removal of water, oxygen and dust.

R&D and production of battery industry (Lithium ion battery, powder battery, solar cell, lithium ion phosphate battery ).

R&D and manufacture of special lamp (HD lamp, metal halide lamp, ceramic metal halide lamp).

Welding (resistance welding, TIG welding, laser welding, plasma welding, brass solder)

R&D and production of OLED

R&D and production of pharmaceuticals

R&D and production of super capacitors

Fine chemical industry

Nuclear industry

R&D and production of new energy materials


Specifications


Specifications of Standard Model of Purification Glove Box
No.Model No.Box DimensionsTotal DimensionsOperating Sides

Numbers

of Gloves

Options
1GBP800S-21200*800*930mm1915*830*1830mmSingle2Single or double purification columns
2GBP1000S-21200*1000*930mm1915*1060*1830mmSingle2Single or double purification columns
3GBP1000D-41200*1000*930mm1915*1060*1830mmDouble4Single or double purification columns
4GBP1200S-21200*1200*930mm1915*1260*1830mmSingle2Single or double purification columns
5GBP1200D-41200*1200*930mm1915*1260*1830mmDouble4Single or double purification columns
6GBP800S-31500*800*930mm2215*1060*1830mmSingle3Single or double purification columns
7GBP1000S-31500*1000*930mm2215*1060*1830mmSingle3Single or double purification columns
8GBP1000D-61500*1000*930mm2215*1060*1830mmDouble6Single or double purification columns
9GBP1200S-31500*1200*930mm2215*1260*1830mmSingle3Single or double purification columns
10GBP1200D-61500*1200*930mm2215*1260*1830mmDouble6Single or double purification columns
11GBP800S-41900*800*930mm2615*1060*1830mmSingle4Single or double purification columns
12GBP1000S-41900*1000*930mm2615*1060*1830mmSingle4Single or double purification columns
13GBP1000D-81900*1000*930mm2615*1060*1830mmDouble8Single or double purification columns
14GBP1200S-41900*1200*930mm2615*1260*1830mmSingle4Single or double purification columns
15GBP1200D-81900*1200*930mm2615*1260*1830mmDouble8Single or double purification columns

Notes:
Cabinet water and oxygen content under the standard condition:
Water content ≤1ppm, oxygen content≤1 ppm (Note: Standard condition is that an atmospheric pressure, constant temperature of 20 degree).
Leakage Rate: ≤0.05Vol%/ h (subject to change value of oxygen content in box)
Used Gas:
a) Working Gas: N2,Ar,He and etc.
b) Controlling Gas: Compressed air or Inert Gas.
C) Restoring Gas: Mixed gas of working gas and hydrogen.

When only a water removal system or an oxygen removal system is present, the composition of the restoring gas will mirror that of the working gas.
Remarks: Each single-sided box, furnished with four gloves, is combined to create a comprehensive glove box system. The quantity of these assembled boxes can be adjusted according to the customer's individual needs. Likewise, the number of purification columns is customized to align with the customer's specific demands.

Technical Parameters


TECHNICAL DATA OF TENCAN INERT GAS GLOVE BOX WITH PURIFICATION SYSTEM
ItemsData

Water content at standard conditions (Note: Standard conditions refer to one atmospheric pressure and a constant temperature of 20 degrees Celsius).

≤1ppm

Oxygen content at standard conditions (where standard conditions are defined as one atmospheric pressure and a constant temperature of 20 degrees Celsius).

≤1ppm
Max Vacuum Degree which the transition cabinet bears<100pa
Leakage Rate≤ 0.05vol%/h
Gas presure range inside the box-3000pa~+3000pa

Functions


FUNCTIONS OF TENCAN INERT GAS GLOVE BOX WITH PURIFICATION SYSTEM
Items

Descriptions

Automatic Control

Controlled and monitored automatically by the program control unit.

Box body gas replacement
(manual/automatic)
Before its initial operation, the air inside the cabinet needs to be replaced with inert gas or nitrogen. This task can be efficiently handled either by utilizing the system-provided automatic gas replacement function of the cabinet, or through manual gas exchange procedures.
Transition cabinet replacement
(manual/automatic

Upon placing material inside a box, the gas transition cabinet needs to be swapped out. This process can be facilitated either through the airlock system's automatic gas exchange function or by manually carrying out the gas replacement.

Gas purification control

After setting up the work status and results, the system purification procedures set to “Auto”, the system will automatically maintain the atmosphere condition of the cabinet,then the system will automatically complete the work; you may also choose manual control.

Pedal air-pressure control

Utilize the foot controller to regulate gas pressure within the cabinet by either inflating or exhausting the system.

Reduction of purification system

Purification materials reduction is done automatically by the system, we only need to set the conditions of system reduction. Open “reduce”, the system will automatically complete reduction, the whole process does not need to monitor.

On-line operating condition detection

The control system provides users with the operating condition detection function of the component of the equipment. Such function can be used to observe operating condition of the component and inspect fault source of each function and component.

System parameter setting

System settings function, users can set the system parameters to achieve the desired working conditions and feature set.

Data logging function

The system provides operating parameter record of the equipment, this record can be traced back to monitor production or experiment.

Control of gas reserve function

When the temporary cutting of control-gas supply, or cutting off control-gas source for some time, the control-gas reserve will protect the equipment continue working.

Standby function of cycle gas cooled

Purification system provides a heat exchange for cooling the circulating gas, can be used alone by injecting the coolant to control the temperature of the circulating gas.

Multi-level safety system

The control system sets up a variety of security features, include multilevel security tips, alarm and disable function, to protect the safety of operating personnel and equipment.

Protection function when purification
cycle blocked

When the circulation system is blocked, the control system prompts alerts, and take the initiative to adjust the speed of air, in order to protect the motor, though this function can also check out system cycle blocked, pipeline poor, filter control dust obstruction, and other issues.