Add to Cart
High Sensitive PDGFA Rabbit Sandwich ELISA Kit Platelet-derived
Growth Factor Subunit A ELISA Kit
Cat.No E0031Rb
Standard Curve Range: 5ng/L - 1000ng/L
Sensitivity: 2.78ng/L
Reagent Provided
Components | Quantity |
Standard Solution (1280ng/L) | 0.5ml x1 |
Pre-coated ELISA Plate | 12 * 8 well strips x1 |
Standard Diluent | 3ml x1 |
Streptavidin-HRP | 6ml x1 |
Stop Solution | 6ml x1 |
Substrate Solution A | 6ml x1 |
Substrate Solution B | 6ml x1 |
Wash Buffer Concentrate (25x) | 20ml x1 |
Biotinylated Rabbit PDGFA Antibody | 1ml x1 |
User Instruction | 1 |
Plate Sealer | 2 pics |
Zipper bag | 1 pic |
Material Required But Not Supplied
Intended Use
This sandwich kit is for the accurate quantitative detection of
Rabbit Platelet-derived Growth Factor Subunit A (also known as
PDGFA) in serum, plasma, cell culture supernates, cell lysates,
tissue homogenates.
Precautions
Specimen Collection
Serum Allow serum to clot for 10-20 minutes at room temperature.
Centrifuge at 2000-3000 RPM for 20 minutes.
Plasma Collect plasma using EDTA or heparin as an anticoagulant.
Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C
within 30 minutes of collection.
Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for
approximately 20 minutes. When collecting pleuroperitoneal fluid
and cerebrospinal fluid, please follow the procedures
above-mentioned.
Cell Culture Supernatant Collect by sterile tubes when examining secrete components.
Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect
the supernatants carefully. When examining the components within
the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the
cell concentration of approximately 1 million/ml. Damage cells
through repeated freeze-thaw cycles to let out the inside
components. Centrifuge at 2000-3000 RPM for approximately 20
minutes.
Tissue and other body fluids Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly
and weigh before homogenization. Mince tissues and homogenize them
in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or
freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20
minutes.
Note
*Sample can't be diluted with this kit. Owing to the the material we use to prepare the kit,
the sample matrix interference may falsely depress the specificity
and accuracy of the assay.
Summary
1. Prepare all reagents, samples and standards.
2. Add sample and ELISA reagent into each well. Incubate for 1 hour
at 37°C.
3. Wash the plate 5 times.
4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.
5. Add stop solution and color develops.
6. Read the OD value within 10 minutes.
Calculation of Result
Construct a standard curve by plotting the average OD for each
standard on the vertical (Y) axis against the concentration on the
horizontal (X) axis and draw a best fit curve through the points on
the graph. These calculations can be best performed with
computer-based curve-fitting software and the best fit line can be
determined by regression analysis.