Home /General Assay & Diagnostic Apparatuses /

Insulin / INS Human Sandwich Elisa Kit Under 2 - 8°C Storage Condition

Insulin / INS Human Sandwich Elisa Kit Under 2 - 8°C Storage Condition

Brand Name:BT Lab
Certification:CE, ISO9001:2005, MSDS
Model Number:Cat.No E0010Hu
Minimum Order Quantity:Negotiation
Delivery Time:1-3 business days, bulk order within one week
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China
Supplier`s last login times: within 34 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

96 wells Human specificity and precision Insulin INS ELISA Kit


Reagent Provided

ComponentsQuantity
Standard Solution (80mIU/L)0.5ml x1
Pre-coated ELISA Plate12 * 8 well strips x1
Standard Diluent3ml x1
Streptavidin-HRP6ml x1
Stop Solution6ml x1
Substrate Solution A6ml x1
Substrate Solution B6ml x1
Wash Buffer Concentrate (30x)20ml x1
Biotinylated human INS Antibody1ml x1
User Instruction1
Plate Sealer2 pics
Zipper bag1 pic

Specimen Collection

Serum Allow serum to clot for 10-20 minutes at room temperature. Centrifuge at 2000-3000 RPM for 20 minutes.

Plasma Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 2000-3000 RPM at 2 - 8°C within 30 minutes of collection.

Urine Collect by sterile tube. Centrifuge at 2000-3000 RPM for approximately 20 minutes. When collecting pleuroperitoneal fluid and cerebrospinal fluid, please follow the procedures above-mentioned.

Cell Culture Supernatant Collect by sterile tubes when examining secrete components. Centrifuge at 2000-3000 RPM for approximately 20 minutes. Collect the supernatants carefully. When examining the components within the cell, use PBS (pH 7.2-7.4) to dilute cell suspension to the cell concentration of approximately 1 million/ml. Damage cells through repeated freeze-thaw cycles to let out the inside components. Centrifuge at 2000-3000 RPM for approximately 20 minutes.

Tissue Rinse tissues in PBS (pH 7.4) to remove excess blood thoroughly and weigh before homogenization. Mince tissues and homogenize them in PBS (pH7.4) with a glass homogenizer on ice. Thaw at 2-8°C or freeze at -20°C. Centrifuge at 2000-3000 RPM for approximately 20 minutes.


Assay Procedure

  1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.
  2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.
  3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.
  4. Add 40μl sample to sample wells and then add 10μl anti-INS antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells (Not blank control well). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.
  5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.
  6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.
  7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.
  8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.

Cat.No E0010Hu

Standard Curve Range: 0.2mIU/L - 60mIU/L

Sensitivity: 0.11mIU/L

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

* This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.


References

Minn A.H., Kayton M., Lorang D., Hoffmann S.C., Harlan D.M., Libutti S.K., Shalev A.
Lancet 363:363-367(2004)


China Insulin / INS Human Sandwich Elisa Kit Under 2 - 8°C Storage Condition supplier

Insulin / INS Human Sandwich Elisa Kit Under 2 - 8°C Storage Condition

Inquiry Cart 0