Load Cell IPW2D 72kg C3 Dynamic Weighing force sensor Single Point weight sensor 2mv/v for Digital Scale Aluminum IP67

Brand Name:inntronic
Model Number:IPW2D
Minimum Order Quantity:1pc
Delivery Time:15-30 days
Payment Terms:L/C
Place of Origin:China
Contact Now

Add to Cart

Site Member
Location: Hangzhou Zhejiang China
Address: #201,Shunda Road, Yuhang Economic Area, Hangzhou,China
Supplier`s last login times: within 37 hours
Product Details Company Profile
Product Details

IPW2D 7.2kg to 72kg Single Point Load Cell for dynamic weighing

Dynamic Weighing Single Point Load Cell , Aluminum Material Electronic Load Cell for static weighing
Special features

− Accuracy class C3 with OIML-R60 test report

− Max. capacities: 7.2 kg ... 72 kg

− Off center load compensated(OIML R76)

− Degree of protection IP67(according to EN 60 529)

− Shielded connection cable

− optimized for dynamic weighing applications

Optional:

− Connection cable in six wire circuit

− Different cable lengths

− Aligned output, suitable for

− Aligned output, suitable for connectionin parallel


TypeIPW2D
Accuracy class1)C3; C3MR
Number of load cell intervals (nLC)3000
Maximum capacity (Emax)2))kg7.212183672

Minimum LC verification interval (vmin)

Accuracy class C3

g1251020

Temperature effect on

zero balance (TK0)

Accuracy class C3


% v.

Cn /

10 K


±0.0194±0.0233±0.0389±0.0389±0.0389

Minimum LC verification interval (vmin)

Accuracy class C3MR

g0.512510

Temperature effect on

zero balance (TK0)

Accuracy class C3MR

% v.

Cn /

10 K


±0.0097±0.0116±0.0155±0.00194±0.0194
Max. platform sizemm380 x 380
Sensitivity (Cn)mV/V2.0±0.2
Zero balance0±0.1

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40℃ [+68 ... +104℉]

−10 ... +20℃ [+14 ... +68℉]

% v.

Cn /

10 K


±0.0175

±0.0117

Hysteresis error (dhy)3)% of Cn±0.0166
Non-linearity (dlin)3)±0.0166
Minimum dead load output return (DR)±0.0166
Off center load error4)±0.0233
Input resistance (RLC)Ω300 ... 500
Output resistance (R0)300 ... 500
Reference excitation voltage (Uref)V5
Nominal range of excitation voltage (BU)1 ... 12
Insulation resistance (Ris) at 100 VDC> 2
Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]
Service temp. range (Btu)−10 ... +50 [+14 ... +122]
Storage temp. range (Btl)−25 ... +70 [−13 ... +158]

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150

160

Lateral load limit (Elq), static

% of

Emax

300
Breaking load (Ed)300
Weight (G), approx.kg0.25

Protection class according to

EN 60 529 (IEC 529)

IP67

Material: Measuring element

Coating

Cable sheath

Aluminum

Silicone rubber

PVC


China Load Cell IPW2D 72kg C3 Dynamic Weighing force sensor Single Point weight sensor 2mv/v for Digital Scale Aluminum IP67 supplier