FFU description

FFU is abbreviation of Fan Filter Unit. lt is a modular terminal air supply devicewithits own power and filtering effect, lts main function is to inhale the air from thetopof the FFU by the fan and filter it by HEPA, and the filtered clean air is evenlysentout at the air velocity of 0.45m/s+20% on the entire air outlet surface to meetthecleanliness requirements of the clean environment. lt is mainly installed onceilingkeels and equipment machines in clean areas and working areas.


The FFU can be modularly connected and used, making the FFU widely used in clean rooms, dust-free consoles, dust-free production lines, assembled clean rooms, and local 100-class applications. FFU has an early and high-efficiency two-stage filter. The fan draws in air from the top of the FFU and is filtered by a primary and high-efficiency filter. The filtered clean air is delivered at a constant speed of 0.45 M/S±20% across the entire outlet surface. It provides high-quality clean air for clean rooms and micro-environments of different sizes, different cleanliness levels. In the newly-built clean room and clean plant type renovation and refurbishment, the cleanliness level can be improved, noise and vibration can be reduced, and the cost can be greatly reduced. The installation and maintenance are convenient, and it is an ideal component for a clean environment.


FFU advantages

1). Extremely low operation consumes power and reduces costs.

2, built-in air duct diversion system, reduce noise and pressure loss, improve fan efficiency.

3), can easily match the various brands of T-GRID and HEPA, ULPA.

4). The fan filter unit fan adopts high efficiency centrifugal fan, which can provide high air volume and high static pressure conditions. The service life requirement is up to 50,000 hours.

5), suitable for use in cleanliness class Class 1-1000 class clean room.

6), especially suitable for assembly into ultra-clean production lines, can be arranged according to process needs for a single use, can also be more than one series to form 100 assembly line

7). Before the products leave the factory, they are all tested according to US Federal Standard 209E using dust particle counters to ensure quality.


Product Feature


1,Negative pressure ventilation
2,Save space
3,Shorten construction period

4,Reduce operating costs

5,Convenient and fast control
6,lt is flexible and easy to replace, install and move

FFU Standard type

  • The degree of cleanliness from class 1 up to 100,000 can be set and it can be set at individual area.
  • Because the back in the ceiling is a low-pressure area, the potential of the leakage is extremely low.
  • Bay method or through the wall method is possible by the arrangement of the layout of FFU.
  • The volume of the air flow can be set at each area.
  • Flexible increase or change of the clean room is possible by the arrangement of Fan Filter Unit.

Product Structure


1,Speed control switch

2,Pin socket

3,Corner code

4,Primary filter

5,Haft

3. FFU Parameter

ModelFFU-KLC920FFU-KLC1175FFU-KLC1225Unit
Size920×615×3501175×575×3501225×615×350mm
plenum chamber materialsAluminized zinc plate/stainless steel.Aluminized zinc plate/stainless steel.Aluminized zinc plate/stainless steel.
Air flow80010001200m3/h
Average wind velocity0.4/0.45/0.50.4/0.45/0.5/0.4/0.45/0.5m/s
Extemal static pressure97(10mmAq)97(10mmAq)97(10mmAq)pa
Hepa filter size915×610×691170×570×691220×610×69mm
Efficiency0.12um@99.99%0.12um@99.99%0.12um@99.99%
Filter initial pressure loss180Pa@0.45m/s180Pa@0.45m/s180Pa@0.45m/s
Power180Pa@0.45m/s180Pa@0.45m/s180Pa@0.45m/s
Fan vibration coefficient0.2-0.5mm/s0.2-0.5mm/s0.2-0.5mm/s
Power dissipation123123172W
Weight242831Kg
Noise535555dB

Success case show



Company Information


Dongguan Yaning Purification Equipment Co.,Ltd is located in Dongguan, the advanced manufacturing center of the Guangdong-Hong Kong-Macao Greater Bay Area. It is an integrated supplier of clean technology solutions integrating technology, research and development, design, manufacturing, sales and installation. The company has more than 200 employees, a plant area of more than 30,000 square meters, and an annual output value of more than 300 million RMB. With more than ten years of independent R&D and innovation, YANING Purification has obtained more than 30 technical patents and has become a national high-tech enterprise. It has passed the ISO9001:2015 quality management system certification and ISO14001:2015 environmental management system certification, and won the title Guangdong "Abide by contracts and keep promises" Enterprise, Famous Brand Enterprise in Guangdong Province, Top Ten Brands in China's Purification Industry and other honorary titles.