Resistive 400v 1500kw Load Bank 3 Phase AC Variable For Generator Testing

Product Description


According to the special requirements of users on site, in the agreement the technical standards Intelligent Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.


Technical Parameters

Rating Voltage/Frequency400VAC 50Hz/60Hz,3phase 4 wire
Max Load PowerResistive Load: 1500kW
Load Step

Resistive Load:16 steps
1,2,2,5,10,10,20,50,100,100,200,200,200,200,200,200kW

Power Factor1
Load Tolerance(each step)±5%
Load Tolerance(overall)±3%
Display Precision0.5 class
Control Power SupplyExternal 415VAC, 3phase 4wire 50Hz
Wire Connection

Load Power Supply Input——Copper bar (star connection)
Control power supply input——Connector bar

Communication InterfaceRS232 and RS485
Insulation ClassF
Duty CycleContinuous
CoolingForced air cooling, horizontal air inlet and air outlet
TransportationHoisting, there are lifting lug in top of case and wheel castors on the bottom
Chassis colorGray(RAL7035)
Size

Approximately 1900mm*2900mm*2100mm
(Width *Length *Height)

WeightApproximately 2000kg
Ambient Temperature-10℃~+50℃
Relative Humidity≤95%
Altitude≤2500meters
Atmospheric Pressure86~106kPa


Product Advantage

1.High Efficiency Data Management: display real-time testing data, generate form, curve graph or report automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.

2.Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment


Application

1.Manufacturers of standby power generators commonly use load banks to test and tune newly assembled units

2.generator has been set up in a test cell within the factory, a test engineer uses the load bank to apply a discrete, selectable electrical load to the generator and measure the response stability and endurance.