Parallel Testing High Power Resistor Load Bank 3 Phase 4 Wire For Generator

Brand Name:KAIXIANG
Certification:ISO9001
Model Number:1440 KW
Minimum Order Quantity:ONE SET
Delivery Time:ONE MONTH AFTER GET DEPOSIT
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Shijiazhuang Hebei China
Address: No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Ocean Engineering Dummy Electrical Load Bank 1440KW Generator Test


Product Description


The system consists of 1 sets of 1440kw load bank. The system is made up of two parts of measurement and control and load, mainly including the dry type ac load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.


Technical Parameter


Rating Voltage/Frequency480VAC/60Hz, 3 phase 4 wire, line
Max Rated voltage504V 60HZ
Rated power1440kW
Load Step

A Phase 10,20,20,,20,50kw

B phase 10,20,20,,20,50kw

C phase 10,20,20,,20,50kw

PF(Power Factor)1
Load Tolerance (each step)±5%
Load Tolerance(overall)±3%
Display Precision0.5 class
Control Power380VAC/50Hz, 3 phase 4 wire,
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Connector-bar

InsulationF
Protection GradeIP21
communication interfaceRS485,RS232
Casing Dimensions and Coolingabout 2800*1900*2400mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling
WeightAbout 1800kgs/set
TransportationHoisting, there are lifting lug in top of casing
Casing ColorGrey(RAL7035)
Ambient Temperature-10℃~+50℃
Relative Humidity≤95%
Altitude≤2500 meter
Atmospheric Pressure86~106kPa
ContactorSchneider
FuseDELIXI
MCUINFINEON
Data processing softwareKaixiang(self-developed)
Alloy ResistanceKaixiang(self-developed)

Product Advantage


1. Manual load: input power and power factor.

2. Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100%, etc preset order to make automatic load testing.

3. Parallel testing: when several load banks parallel working, parameters of each load bank can be displayed and recorded, so do the final parameters of paralleling working.

4. Real-time parameter: Current, voltage, power, power factor, frequency, time, etc could be displayed by software.


Application

Load banks may be installed in a diesel powered generator set to apply the additional load required to ensure the engine fully consumes the fuel in the combustion process. If a diesel engine is not operated under adequate load, unconsumed fuel will collect in the engine’s exhaust stack and form an oily coating.



China Parallel Testing High Power Resistor Load Bank 3 Phase 4 Wire For Generator supplier

Parallel Testing High Power Resistor Load Bank 3 Phase 4 Wire For Generator