Resistive Power Capacitive Load Bank 3630 Kvar For Generator Testing

Brand Name:KAIXIANG
Certification:ISO9001
Model Number:AC440V(690V)-6050kVA-RL
Minimum Order Quantity:1 set
Delivery Time:Within 30 working days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Shijiazhuang Hebei China
Address: No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Ocean Engineering 440V(690V) 6050kVA Inductive Load Bank For Generator Testing

Product description

Load Banks are used with Engine Generators, Battery Systems, UPS Systems, Inverters, Ground Power Units, Auxiliary Power Units, Aircraft Power Generators, Wind Generators, and Hydro Generators.


Technical Parameter


Rating Voltage/Frequency

angle form 440VAC/60Hz,

Star class 690v 50hz

Max Rated power

Apparent Power: 6050kVA

Resistive Power: 4840kW

Reactive Power: 3630kvar

Load Resolution

Resistive Load: 1.2.2.5.10.10.20.20.50.100.200.200.200.200.200.200.200.200.200.200.200kw

Reactive load:1.2.2.5.10.10.20.20.50.100.200.200.200.200.200.200.200.200kvar

PF(Power Factor)0.8
Load Tolerance (each step)±5%
Load Tolerance(overall)±3%
Display Precision0.5 class
Control Power380VAC/50Hz,
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Connector-bar

Communication InterfaceRS485,
Casing Dimensions and Coolingabout 9150*2350*2896mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling
WeightAbout 25000kgs/set


Product Advantage


1. Communication type: through RS232, RS485 or USB interface.

2. Load mode: manual load or automatic load.

3. Manual load: input power and power factor.

4. Automatic load: User can set several periods of power and time, and in turn of 0%→25%→50%→75%→100%, etc preset order to make automatic load testing.


Application

Generators installed in the field must be periodically tested and exercised to ensure that it will operate as intended when a power outage actually occurs. Service groups use load banks to apply a load that mimics the load of the facility the generator is protecting. Any problems with the generator can then be identified and rectified in a non-critical environment.