1500 KVA 1200KW Inductive Load Bank Resistive With Short Circuit Protection

Brand Name:KAIXIANG
Certification:ISO9001
Model Number:AC440V-1500kVA
Minimum Order Quantity:1 set
Delivery Time:Within 30 working days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Shijiazhuang Hebei China
Address: No33 Wangshan Road, Green Island Economic Development Zone, Shijiazhuang, China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Ocean Engineering 440V 1500kVA Inductive Load Bank For Generator Testing

Product description

A resistive load bank, therefore, removes energy from the complete system: load bank from generator—generator from prime mover—prime mover from fuel. Additional energy is removed as a consequence of resistive load bank operation: waste heat from coolant, exhaust and generator losses and energy consumed by accessory devices. A resistive Load Bank impacts upon all aspects of a generating system.


Technical Parameter


RatingVoltage/Frequency

angle form 440VAC/60Hz,

Star class 400v 50hz

Max Rated power

Apparent Power: 1500kVA

Resistive Power: 1200kW

Reactive Power: 900kvar

Load Resolution

Resistive Load: 1.2.2.5.10.10.20.50.100.200.200.200.200.200kw

Reactive load:1.2.2.5.10.10.20.50.100.200.200.200.200.200kvar

PF(Power Factor)0.8
Load Tolerance (each step)±5%
Load Tolerance(overall)±3%
Display Precision0.5 class
Control Power380VAC/50Hz,
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Connector-bar

Communication InterfaceRS485,
Casing Dimensions and Coolingabout 6058*2438*2896mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling
WeightAbout 12000kgs/set


Product Advantage


1. User can press the emergency stop button in the panel to unload immediately when the load bank is abnormal while working.

2. Over-load: Automatic load dump and give alarm when voltage is over safety thresholds.

3. Over-heat protection: Automatic load dump and give alarm when temperature is over safety thresholds.

4. Short Circuit Protection: Fuse could avoids damage to equipment when short circuit or current overload.


Application

KX Load Banks can be used to satisfy the requirements for emergency stand-by power systems. These requirements concern acceptance testing and periodic on-site testing and maintenance of emergency and stand-by power systems. The essence of the requirements is that emergency and stand-by power systems are to be tested under load.


China 1500 KVA 1200KW Inductive Load Bank Resistive With Short Circuit Protection supplier

1500 KVA 1200KW Inductive Load Bank Resistive With Short Circuit Protection