AUPO thermal cutoff fuse was established in 1986 ,which is an advanced high-tech enterprise that specialized in thermal links (thermal protectors) research and development, production and sale. Developed more than 10 series 100 models of thermal links, and our annual productivity achieves 1 billion pieces. The AUPO strictly operates under superior management system and quality assurance system based on ISO9001. Also our products have been recognized and certificated by a number of domestic and foreign safety laboratories including UL, CUL, VDE, TUV, CSA, PSE, KTL-EK, CCC, and so on. Our own laboratory has been certified by UL and VDE as the witness laboratory.
______________________________________________________________________________ Download________
Product Overview
The thermal cutoff fuse (TCO) are non resetting, thermally
sensitive, single pole, normally closed devices and are intended to
be used in various appliances.A temperature sensitive thermal
cutoff fuse melts and opens electrical contacts when temperatures
exceed the rating of the thermal fuse. Thermal cutoff fuse are
providing protection against potentially hazardous overheating
conditions in billions of products around the world.
Standard product offerings include:
Thermal Cutoff Fuse
* Metallic Case type (Axial, Spring Action, Current : 10A ,15A)
* Low melting alloy type ( Axial, Surface tension type, Current :
2A, 5A)
Note that the TCO shall be connected at the readily detectable
location when abnormal conditions such as thermostat failure, fan
failure, locked rotor, dry operation, etc.,might occurr in the
appliance.
TCO is designed to lessen the heat created from TCO itself, but
there may be a difference between the
ambient temperature and operating temperature of TCO due to wrong
connection method.
In order to minimize the difference between ambient temperature and
operating temperature of TCO, it is recommended that the creation
of heat can be minimized around the TCO connected area under normal
operating condition, but the heat generation can be maximized at
TCO connected area under abnormal condition.
Specification
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
○ Pending;● Approved |
Operation Description
Dimension
unit:mm
Application
PRECAUTION FOR LEAD CONNECTION
* Be careful to be free from damage, burn, nick, crack or
overheating at TCO seal or body.If there are such damage as above,
do not use.
* Experimental assembly trials should be made to check the damage
of lead wire, seal or TCO body.
* When connecting wire to TCO, it is recommended that splice or
terminal shall be used. The material of splice or terminal should
be corrosion resistant.
* When securing the splice or terminal to TCO, be careful not to
damage the TCO body. The material of splice or terminal should be
low heat resistace. Be careful not to cause excessive overheating
due to poor connection method. It should be noted that the
connection wire shall be flexible standard wire. If using solid
wire, use the bending process.
SOLDERING OF LEAD
The following points should be noted if soldering is used to
connect TCO lead.
* Do soldering work on lead as far away from the TCO body if
possible.
* Be careful to minimize the heat transfer to TCO body. When proper
means to prevent the heat transfer is not provided, TCO seal or
body may be damaged and broken-down.
* To shorten the working time, employ pre-soldering process at the
intended soldering area.
* Soldering Method to prevent heat.(use heatsink)
* Mechanical security must not depend on solder alone.
* Electric current must not pass through inner electric contact or
the case of TCO when soldering. The passing of excess current
damages the TCO element or case.
* Tensile strength of lead
Pull force shall not be over 2kg and push force shall not be over
0.5 kg.
* Strength of Case
Applying the excessive force to tie the case body causes
deformation and effects normal operation of TCO.Since this may
cause the fuse to not properly operate, be sure to avoid the
excessive tying force.
* Functioning Temperature Test
Install the TCO in a chamber and gradually increasing temperature
upto 20°C lower than Tf, then if the temperature of the chamber and
the testing products are made equal, the temperature is increased
1°C per minute, then the fuse will function within the specified
tolerance.
* Temperature Increase Test
When normal operating voltage and current are applied to the TCO in
ambient temperature (20~25) °C the temperature of the TCO will go
up.But the increase of temperature shall not be more than 10°C
* Insulation Resistance
After having operated in temperature test, the insulation
resistance shall be more then 0.2 ohms when tested with 500V
resistance measuring machine.
* Contact Resistance Test
The resistance of the both leads of the TCO should not exceed 1.5
ohms within the 10mm length of the leads.
* Dielectric Voltage Withstand Test
After conducting the Insulation resistance test, the TCO shall be
maintained without breakdown when AC 500V is applied between the
leads of the TCO for 1 Min
.
* Humidity Test
After keeping the TCO in the chamber with humidity 90~95% and specified below condition for 500 hours, the TCO shall pass the Functioning temperature test.
Tf | Chamber Temperature | Humidity |
100 °C less | 40 ± 2 °C | 90~95% |
100 °C over | 65 ± 2 °C |
*Aging Test
After keeping the TCO at the temperature 20 ± 3 °C lower then the Tf for 48 hours,the TCO shall pass the Functioning temperature test
* Temperature Rise Graph
Agency Approvals
PN | UL/CUL | VDE | CCC | PSE | KTL |
BF172 | E140847 | 40005418 | 2003010205052188 | JET0749-32001-1012 | SU05017-11004 |
Company Certificates
Certificate Standard:ISO 9001:2008 | Number:CN99/16675 |
Issue Date:20-Mar-2017 | Expiry Date:15-Sep-2018 |
Issued By:SGS |
Certificate Standard:ISO 14001 | Number:CN13/30311 |
Issue Date:29-Feb-2016 | Expiry Date:15-Sep-2018 |
Issued By:SGS | Scope/Range:Design and manufacture of thermal cutoffs |
Certificate Standard:OHSAS 18001 | Number:CN16/30181 |
Issue Date:05-Feb-2016 | Expiry Date:04-Feb-2019 |
Issued By:SGS | Scope/Range:Design and manufacture of thermal cutoffs |
Factory Photos
FACTORY BUILDING | OEM product lines |
Equipment room | Models room |
Developing new products | Research and development department |
Checkout Room | Finished product checking |
Quality test equipments | Services and Support Department |
Machinery/Equipment for R&D
Molding plastics machine |
Move-printing machine |
Shredding machine |
Silk making machine |
Thermostatic drying cabinet |
Recording instrument |
X-ray machine |