0ZRC0015FF1E Telecom Thermistor PPTC Resettable Fuse TRG015 With Rated Voltage 600V Hold Current 0.15A

Certification:UL,CSA,TUV,RoHS
Model Number:TRG015
Minimum Order Quantity:1000 Pieces
Delivery Time:10 Workdays
Payment Terms:T/T, Western Union,Paypal
Price:Negotiable
Contact Now

Add to Cart

Site Member
Location: Dongguan Guangdong China
Address: NO.27,Jinlanling Street,Taigongling Village Dongguan 523829,Guangdong,China
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

0ZRC0015FF1E Telecom Thermistor PPTC Resettable Fuse TRG015 With Rated Voltage 600V Hold Current 0.15A


Features


• Radial Leaded Devices
• Maximum 600 VAC interrupt fault rating
• Available in matched resistance “bins”
• Ability to withstand lightning surges

• RoHS compliant
• Resettable overcurrent protection
• Fast time-to-trip
• Agency recognition: UL, CSA, TÜV
• Resistance-sorted and matched devices available
• Low parasitic capacitance/flat impedance with frequency


______________________________________________________________________________ Download________


Electrical Perforamces


P/NHold Cu.Trip Cu.Max VoltMax CurrentImpulse Volt.Max.TripPowerResistance(Ω)
IH, (A)IT,(A)Vmax,(v)Imax,(A)Vmax, (V)(A)(Sec.)Pd typ(W)RminRminR1max
TRG0110.110.222503.06001.004.01.07.014.026.0
TRG0150.150.302503.06001.005.01.06.012.022.0
TRG0160.160.322503.06001.007.51.74.010.018.0

Dimension (mm)



P/NABCDEPhysical Characteristics
Max.Max.Typ.Min.Max.StyleLead Φ mmMaterial
TRG0119.012.55.17.64.610.6CU
TRG0159.012.55.17.64.610.6CU
TRG0169.012.55.17.64.610.6CU

Thermal Derating Chart – I hold (Amps)


P/NAmbient Operating Temperature
-40℃-20℃0℃25℃40℃50℃60℃70℃85℃
TRG0110.220.190.170.140.110.100.070.070.06
TRG0150.240.210.180.150.120.110.080.080.06
TRG0160.250.220.190.160.130.120.080.090.07

BENEFITS


• Choice of many product options helps engineers by improving design flexibility

• Compatible with high-volume electronics assembly

• Assist in meeting regulatory equipment requirements

• Help improve line balance

• Applicable for legacy POTS and modern digital communications equipment


APPLICATIONS


• Modems

• Phone sets

• Fax machines

• Phone wall outlets

• Alarm systems

• PBX systems

• MDF modules

• Analog and digital line cards

• T1/E1 equipment

• xDSL modems and splitters

• Powered ethernet systems

• VoIP (Voice over Internet Protocol) equipment

• LAN, WAN equipment

• Customer premise equipment

• Access network hardware


Application Guide for Telecommunications and Networking Devices*


To use this guide, follow the steps below:

1. Select your equipment type from the guide below.

2. Select the type of protection depending on the agency and regional specifications in the second column.

3. Select the form factor for your application.

4. Use the Agency Specification/ PolySwitch Device Selection Guide on the next page to select a specific part number for each application based on the agency requirements.

5. Parts with fast time-to-trip or low resistance are available. Please consult a PolySwitch representative.


Environmental Characteristics


Operating/Storage Temperature........................... -40 °C to +85 °C

Maximum Device Surface Temperature

in Tripped State ................................................. 125 °C

Passive Aging................................ +60 °C, 1000 hours............................ ±15 % typical resistance change

Humidity Aging............................. +60 °C, 90 % R.H. 1000 hours ................ ±15 % typical resistance change

Solvent Resistance............................ MIL-STD-202, Method 215B................................. No change Lead

Solderability................................................. ANSI/J-STD-002

Flammability ......................................... IEC 695-2-2 .......................................................... No flame for 60 secs.

Vibration ........................................... MIL-STD-883C, Method 2007.1, Condition A ....... No change


Test Procedures And Requirements For Model TRG Series


Test Test Conditions Accept/Reject Criteria

Visual/Mech.................................. Verify dimensions and materials ........................... Per MF physical description

Resistance..................................... In still air @ 23 °C.................................................... Rmin ≤ R ≤ Rmax

Time to Trip.................................... 1 A, Vmax, 23 °C ..................................................... T ≤ max. time to trip (seconds)

Hold Current .................................. 30 min. at Ihold ....................................................... No trip

Trip Cycle Life.................................. Vmax, Itrip, 100 cycles.......................................... No arcing or burning

Trip Endurance ............................... Vmax, 24 hours..................................................... No arcing or burning

China 0ZRC0015FF1E Telecom Thermistor PPTC Resettable Fuse TRG015 With Rated Voltage 600V Hold Current 0.15A supplier

0ZRC0015FF1E Telecom Thermistor PPTC Resettable Fuse TRG015 With Rated Voltage 600V Hold Current 0.15A

Inquiry Cart 0