PLC Type 50W - 500W Flame Test Apparatus Horizontal / Vertical UL94 IEC60695-11-4/3

Brand Name:PEGO Group
Certification:Third-Lab Calibration Certificate
Model Number:HVR-4H
Minimum Order Quantity:1 set
Delivery Time:15 working days
Payment Terms:T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Yichun Jiangxi China
Address: No. 317, Yichun South Road ( Happiness Park), Yuanzhou District, Yichun, Jiangxi, 336000, China
Supplier`s last login times: within 34 hours
Product Details Company Profile
Product Details

PLC Type 50W and 500W Horizontal and Vertical Flame Tester According to UL94 and IEC60695-11-4/3


1. Introduction

Horizontal and vertical flame test apparatus is applied to 50W vertical flame test includes V-0, V-1, V-2, horizontal flame tester HB, and 500W vertical flame test includes 5VA, 5VB, HF-1, HF-2 and HBF. It is widely used in the R&D department, QC department and production department of lighting equipment, low-voltage apparatus, household appliance, motor and etc.. And also can be used in the industries of insulation material, plastic, non-metalic material, foam with a density of not less than 250kg/m' and other solid combustible material.

The horizontal and vertical flame test apparatus is controlled by 7-inch color touch screen and PLC. The test apparatus is built-in air exhaust, the front panel is transparent for easy observation of the experimental process, and the shell is made of painted coating metal sheet. Fully independent electrical circuit and gas circuit design for safer use.

Horizontal and vertical flame test apparatus is applied to simulate the fire at the early stage surround the electric and electronics appliance, and then evaluate the degree of fire hazard. It is designed according to UL94, IEC60695-11-4, IEC60695-11-3, IEC60950, IEC707, IEC60695-2-2, ISO1210 and etc.. The flammability test uses a bunsen burner of a specified size and specified gas source (methane or natural gas) to ignite the horizontal or vertical specimen for several times in a certain flame height and a certain flame angle, the fire hazard is evaluated by burning rate, after glow time, after flame time and damage length of the specimen.


2. Parameter

Control system7-inch color touch screen+PLC
BurnerΦ9.5mm ± 0.3mm, 100mm length bunsen burner, source: 50W and 500W
Dip angle00, 200, 450 (manual adjustment)
Timer

Integrated in PLC

Accuracy: ±0.1s

Number of flame0~9999 times (presettable)
Fuel gas98% methane or 37MJ/m3±1MJ/M3 natural gas (prepare by user)
Flow and pressure recordDouble flowmeters and manometer
Gas Pressure0.1Mpa
Gas Flow50W:105±5ml/min or 18±1 mm, 500W:965±30ml/min or 117±3 mm
Flame calibration system

Complete the flame calibration with one key, the system automatically completes the flame calibration 3 times, and the system automatically judges each time. Any unqualified will prompt to re-adjust the flame, and stop the next flame calibration, if qualified, continue to the next flame calibration.

1). Flame temperature required: heat up from 1000C±50C to 7000C±30C within the time of 44s±2s (50W) and 54s±2s (500W)

2). Flame height: 50W: 20±2mm (50W) 500W: 40±2mm (inner), 125±10mm (outer)

3). Thermocouple: Φ0.5mm K type thermocouple (The insulating sleeve heat resist to 1250 ℃), 2 pieces to detect the temperature

4). Temperature measuring copper blocks

Volume of chamber0.75 CBM, matte black background, buit-in exhaust fan, exhaust hole: Φ70mm
AccessoriesPick-up tray, sample clamp, wrapping tissue 12g/m2 ~30g/m2, steel wire mesh, height gauge, cotton, remote-controller and etc.
Dimension of apparatus1260mm(W)*700mm(D)*1300mm (H)
Power supplyAC220V, 50Hz, ≤500W