Add to Cart
GB12831-86 Paint Xenon Lamp Aging Comprehensive Climate Testing Machine
Equipment summary:
Xenon lamp aging testing machine is a comprehensive climate testing machine, in addition to climatic aging test, the lightfastness of materials can be carried out to test, polymer materials exposed at simulated sunlight. It simulates the light, temperature, rainfall, condensing, humidity to test the materials; it can be used for choosing new materials, improving existing materials, or assessment of change in material composition;
Main feature:
Main functions:
Make the samples exposed to the high temperature and alternating back to the circle of light and moisture environment to test the materials. This machine use xenon lamp tube to simulate the sunlight radiation, and use condensation water and spray water to simulate the dew and rain. This instrument only use a few days or weeks time, to realize the condition or the parts aging damage state in outside environment in few months or years. Including fade, color change, fracture, crack, wrinkle, foaming, embrittlement, strength reduction, oxidization and so on.
Applicable industries:
Applied to control the product quality, such as electronic, plastic products, electrical appliances, instruments, food, vehicles, metals, chemicals, building materials, aerospace, medical care and so on.
Technical parameter:
Model | ZL-6011C | |
Testing room D×W×H | 700*500*400mm(W*L*H) | |
Index | Temperature range | RT/10℃~80℃ |
Humidity range | 65~98%R·H | |
Spray time | 1~9999min, adjustable | |
Spray cycle | 1-240min, interval adjustable | |
Irradiance | 350W /㎡~1300 W/㎡(300~800nm) | |
Light source | 2* 1800W air-cooled xenon lamp | |
light source | xenon lamp(air-cooled) | |
Xenon lamp power | 1kw,6kw(longevity:1600H) | |
Temperature and humidity control | Time controller | Import controller from Moeller |
Accurate range | Temperature: ±0.1℃,/ humidity: ±0.1℃R·H | |
Sensor | Platinum resistance Pt100Ω/mv | |
Heating system | Independent system, nickel chromium alloy electric heating type heater | |
Humidity system | stainless steel, external Isolated humidifier | |
Blackboard temperature | Bimetal thermometer blackboard 40℃~110℃(±3℃ | |
Water supply | Humidification water supply with automatic control, xenon lamp cooled by water recycling | |
Temperature controller | Import controller | |
Humidity | Irradiation: 30%~98%RH darkly:50 up to 98%RH | |
Cycle system | low-noise air-conditioning-type motors, multi-leaf-type centrifugal wind wheel | |
Material | Outside material | Advanced spray color plate /SUS304 stainless steel |
Inside material | SUS304 stainless steel | |
Sample holder material | SUS304 stainless steel | |
Insulation | High and low temperature aging of silicone rubber | |
Standard | a set of radiation-proof glass window, dynamic testing sample shelf 1, xenon lamp tube 2 | |
Protector | Leakage, short circuit, over-temperature, water shortages, motor overheating, over-current protection. | |
Power | AC380V±10% 50±0.5HZ , Three-phase five-wire system | |
Environmental temperature | ±5℃~+30℃ ≤85%R·H |
Corresponding standard:
GB12831-86 Vulcanized rubber artificial climate (xenon lamp) Aging
Test Method
GB/T1644.2-1999Plastics laboratory light exposure test method
GB/T8427-89 textile color fastness test, resistance to artificial
light fastness xenon arc
GB/T8430-98 textile color fastness test, resistance to artificial
light fastness xenon arc
GB/T1865-97 Paints, varnishes, artificial weather aging and
artificial radiation exposure
GB/T16991-97 textile color fastness test,
GB/T5137.3-96 simulated climate test method of resistant to
radiation, heat, humidity, burning
GB/T16259-96 color building materials, artificial climate
accelerated aging test method.
GB/T2423.24-95 Electronic and Electrical Products Environmental
Testing Part II: test method, testing SQ: Simulation of solar
radiation on the ground
ASTM G155-05a Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non-Metallic Materials1
Test methods and procedures
Test Method | Fixed: 12 international, national xenon lamp aging test standard |
Program capacity | Editable: 4, can be set to the maximum 1200 block |
Simulate different test conditions | Using different internal and external filter cover: Boro / Boro, |
Quartz/Boro, Quartz/Quartz,Boro/Sodalime | |
Light / dark cycle | Automatic control, monitoring and display |
Operating conditions:
1. Temperature:15℃~35℃
2. Relative humidity: less than 85%RH
3. Without strong vibration and strong electromagnetic field
4. Without high concentration of dust and corrosive materials in
round field
5. No direct sunlight or other sources of heat radiation directly
6. Without a strong airflow around,when need forced air flow
around,air should not be blown directly to the body
7. Test cases should be placed stably, level
8. The sides of the test chamber should keep a certain distance,
convenient maintenance operation.
9. Installation site well ventilated
10. Ground Benign
Equipment safety protection device:
1.Power overload, short circuit protection
2.Ground protection
3.Over temperature protection
4.Water shortage protection
5.In order to protect the equipment,All alarm will automatically
cut off power supply,and with audible reminder