HIM Display Electronic Weighing Indicator Controller For Powder Filling Machine

Brand Name:Supmeter
Certification:CE
Model Number:BST106-M10(FL)
Minimum Order Quantity:1pcs
Delivery Time:3-10 working day
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Site Member
Location: Changsha Hunan China
Address: BUILDING A6, LUGU INTERNATIONAL INDUSTRIAL PARK,CHANGSHA, 410006, CHINA
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

HIM Display Weighing Controller With High Precise For Powder Filling Machine​


Technical Specifications

  • 16-bit Color screen with 800×480[7”] or 1024×600[10.2”] pixel and LED backlight.
  • Graphic user interface and touch operation.
  • Weight Display Range: -99,999~+999,999.
  • Scale Capacity: Setting Range 1~999,999.
  • Scale Division: Optional 1, 2, 5, 10, 20, 50.
  • Display Resolution: 1/100,000.
  • Weight Unit: Optional g, kg, t, lb[pound], oz[ounce], UserSet.
  • Decimal Point Position: Optional 0, 0.0, 0.00, 0.000.
  • Loadcell Interface
  • Max. Connection Quantity: 16 Loadcells (350Ω).
  • Excitation Voltage/Max. Current: DC5V, 250mA.
  • Signal Input Range: 0~12.5mV.
  • Output Sensitivity of Loadcell: 1.0~2.5mV/V.
  • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
  • Sampling Frequency: 800Hz.
  • Special Anti-vibration Digital Filtering Algorithm for precise weighing, stable display and rapid response.
  • Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
  • Gain Drift: ±5ppm/℃.
  • Non-linearity: 0.005%FS.
  • Switch&Analog Signal Interface
  • 9 Definable Normally Open Switch Inputs [DI].
  • 12/18 Definable Normally Open Transistor Switch Outputs [DO]: DC24V, 500mA.
  • 2 Optional&definable Analog Signal Output [AO]: 0~10V/Max.50mA, Non-linearity: 0.05%FS.

  • Digital Communication Interface
  • COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
  • COM[RS232] for connecting RS232 Serial Printer with Baud Rate ‘9600bps’, Parity Check ‘None’, 8 Data Bits and 1 Stop Bit.
  • USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to U-disk.
  • LAN: Optional Ethernet port.
  • Report Print
  • The Batch Records can be printed automatically.
  • Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.

Outline Size

Button Operation

NameOperationState IndicatorAuthorization
【Auto】Auto / Manual [Emergency Stop] switch.

Green: Auto state.

Grey: Manual state.

All Users
【Start】Start.

Green: Running state.

Grey: Stop state.

【Stop】Stop [Valid at Auto-running state].
【Re-run】Clear Alarm & Recover Running.
【E-stop】Emergency Stop.
【Alarm】

Alarm Query / Clear Alarm.

‘Auto/Pause’ state: Recover Running after alarms cleared.

Red: Alarm state.
【Print】Report Print.Green: Auto Print is allowed.
【Lock】

Screen-locking: Locking/unlocking the operating buttons of main user interface.

Auto Screen-locking: Refer to parameter [901].

Flashing Red: Locked.

Grey: Unlocked.

【Menu】Enter Main Menu.
【User】User Login. Display: Operator / Engineer / Admin.
【Lower】Manual Lower Filling Gun.Flashing Green: Filling Gun is moving down.
【Lift】Manual Lift Filling Gun.Flashing Red: Filling Gun is moving up.
【Bulk】Manual Start/Stop Bulk Fill.Green: Working state.
【Med】Manual Start/Stop Medium Fill.
【Drip】Manual Start/Stop Dribble Fill.
【Zero】Manual Zero [No Power-down Protection].Flashing Red.
【Tare】Manual Tare [No Power-down Protection].Flashing Red.
【Clear】Clear Screen: Clear the display values of Filling Weight, Totalized Weight and Batch Count.

Engineer

Administrator



Main User Interface


China HIM Display Electronic Weighing Indicator Controller For Powder Filling Machine supplier

HIM Display Electronic Weighing Indicator Controller For Powder Filling Machine

Inquiry Cart 0