Mini Weighing Force Measuring Controller Digital Weight Indicator With Weight/Force Display


Main Features:

  • Applications: Weight/Force Display, Peak Value Detection&Display Holding, Setpoint DO Output and AO/Digit Transmission.
  • 4 Optional Setpoint DO Output Modes: Weight Limit DO Alarm Mode, Weight Increment DO Output Mode, Weight Decrement DO Output Mode and Weight Section DO Output Mode.
  • EMC design with high anti-jamming capability, suitable for industrial environment.
  • 32-bit ARM CPU with 48MHz clock & higher arithmetic speed.
  • 5 Red LED digital tubes for English character and digit display.
  • Menu&Shortcut mode operation.
  • 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 1280Hz.
  • Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
  • Optional weighing input signal mV, V and mA for connecting ‘【mV】Output Type Loadcell’, ‘【V】Voltage Output Type Weighing Transmitter’ and ‘【mA】Current Output Type Weighing Transmitter’.
  • Auto Zero Initial Calibration after Power-on, Auto Zero Tracking, Zero Fine Adjustment, Zero Calibration and Load Calibration functions available.
  • Optional Data Calibration, Segmenting Span Correction and Segmenting Weight Calculation functions.
  • Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing functions available.
  • 2 Relay switches with normally open and normally closed contacts for outputting upper limit and lower limit alarm signals.
  • 1 Optional and definable analog signal output [AO: 0~20mA].
  • Optional RS232 and RS485 communication ports for connecting Host IPC/PLC and LED Remote Display.
  • With the multitasking mode, the processes of weighing, alarm output and signal transmission will not be interrupted by parameter setting and the other operations.


Technical Specification

  • Executing Standard
  • CMC GB/T 7724-2008PRC National Standard.
  • OMIL R76: 2006International Recommendation.
  • Accuracy Grade: III.
  • Verification Accuracy: 0.03%.
  • Static Weighing Accuracy: 0.2%~0.5%.
  • Display
  • 5 Red LED digital tubes for English character and digit display.
  • Weight Display Range: -9,999~+99,999.
  • Scale Capacity: Setting Range 1~99,999.
  • Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
  • Display Resolution: 1/50,000.
  • Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
  • Display Refreshing Time: Setting Range 0.01~1.00s.
  • Kaypad
  • 4-key keypad for Menu&Shortcut mode operation.
  • Weighing Signal Interface
  • Excitation Voltage / Max. Current 1: DC5V/120mA for 8-350Ω loadcells.
  • Excitation Voltage / Max. Current 2: DC12V/100mA for weighing transmitter.
  • Optional weighing input signal mV, V and mA for connecting ‘【mV】Output Type Loadcell’, ‘【V】Voltage Output Type Weighing Transmitter’ and ‘【mA】 Current Output Type Weighing Transmitter’.
  • 【mV】Signal Input Range: 0~19.5mV [Output Sensitivity of Loadcell: 1.0~3.5mV/V].
  • 【V】Signal Input Range: 0~2.5V, 0~5V, 0~10V.
  • 【mA】Signal Input Range: 0~20mA.
  • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
  • Sampling Frequency: 1280Hz.
  • Special anti-vibration digital filtering algorithm.
  • Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
  • Gain Drift: ±5ppm/℃.
  • Non-linearity: 0.005%FS.
  • Switch&Analog Signal Interface
  • 2 Relay switches with normally open and normally closed contacts for outputting upper limit and lower limit alarm signals.
  • Contact Capacity of Relay Switch: AC250V/DC24V, 1A.
  • 1 Optional&Definable Analog Signal Output [AO]: 0~20mA, Non-linearity: 0.05%FS.

  • Digital Communication Interface
  • COM1: Optional RS232.
  • COM2: Optional RS485.
  • Connectable: Host IPC/PLC and LED Remote Display.
  • Operating Specification
  • Operating Voltage: DC24V±20%.
  • Max. Power Consumption: 5W.
  • Outline Size: 107×60×100mm [W×H×D].
  • Panel Cut-out Size: 94×47mm [W×H].
  • Operating Temperature: -25℃ to +45℃.
  • Storage Temperature: -30℃ to +60℃.
  • Relative Humidity: Max. 85%RH.
  • Protection Level of Front Panel: IP65.
  • Weight: Approx. 0.3kg.

Keypad Operation

If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.


Menu Operation
Key NameDescription
【■】Enter Main Menu / Exit.
8Enter / Save / Alarm Acknowledge.
【►】

Cursor shifts right.

Display the previous option.

【▲】

Display the next interface or option.

Digit input: +1 ( 0~9 loop).


Quick Operation Mode A

Parameter [904]= ‘0. dE’ [Default Set]

Key NameDescription
【■】*
  • Key-locking.
  • Key-unlocking.

【►】

(【SET】)

Setpoint parameters setting.

【►】*

(【ZERO】)

(【→0←】)

  • [-ZEro]: Zero Calibration with Power-down Protection and Clearing Tare Weight.
  • [≡ZEro]: Zero Fine Adjustment without Power-down Protection and without Clearing Tare Weight.
  • The controller will switch to Gross Weight display.

【▲】*

(【TARE】)

(【→T←】)

  • [≡tArE]: Manual Tare without Power-down Protection.
  • [-PStr]: Preset Tare Weight with Power-down Protection.
  • [-rStr]: Clear Tare Weight with Power-down Protection.
  • The controller will switch to Net Weight display.

8

(【G/N】)

Gross Weight / Net Weight / Net Weight Peak Value display switch.

8】*

(【CLS】)

  • [-CLS] : Clear Screen [Clear the display value of Peak Value].

Quick Operation Mode B

Parameter [904]= ‘1. Au’

Key NameDescription
【■】*
  • Key-locking (Excluding Key【ZERO】&【TARE】).
  • Key-unlocking.

【►】

(【ZERO】)

(【→0←】)

  • Zero Calibration with Power-down Protection and Clearing Tare Weight.
  • The controller will switch to Gross Weight display.

【▲】

(【TARE】)

(【→T←】)

  • Manual Tare with Power-down Protection.
  • The controller will switch to Net Weight display.

8

(【G/N】)

Gross Weight / Net Weight / Net Weight Peak Value display switch.

8】*

(【CLS】)

  • [-CLS] : Clear Screen [Clear the display value of Peak Value].