500L/h 800ppm Acidic Electrolyzed water machine for Chicken Farm

Brand Name:Geemblue
Certification:ISO9001 CE
Model Number:GBA-800L-HCLO
Minimum Order Quantity:1 set
Delivery Time:25-35 work days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: ROOM 801,BUILDING 2-10, CHAOTONG MANSION, NO.233 GUANGYUAN MIDDLE ROAD, BAIYUN DISTRICT, GUANGZHOU, CHINA.
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

500L/h 800ppm Acidic Electrolyzed water machine for Chicken Farm


Introduction


Acidic Electrolyzed water machine is a device used to produce hypochlorous acid solution. Hypochlorous acid (HClO) is a strong oxidant with highly efficient sterilization and disinfection capabilities, and is widely used in medical and health care, food processing, agricultural breeding, public environmental disinfection, and other fields.


Working Principle

The working principle of a hypochlorous acid generator is usually based on electrolysis technology. By electrolyzing a sodium chloride (NaCl) solution (i.e., brine) with a certain concentration, under the action of electrodes, water molecules (H₂O) are decomposed into hydrogen ions (H⁺) and hydroxide ions (OH⁻). Chloride ions (Cl⁻) combine with hydrogen ions to generate hypochlorous acid molecules (HClO) and hydrogen chloride (HCl).


Application for different area


Advantages of Acidic Electrolyzed water machine


(I) Highly efficient sterilization and disinfection


Hypochlorous acid can quickly kill microorganisms such as bacteria, viruses, fungi, and spores. It has high sterilization efficiency and fast speed. The killing rate of common pathogenic bacteria such as Escherichia coli, Staphylococcus aureus, and Candida albicans can reach more than 99.9%.

(II) Safe and environmentally friendly


The hypochlorous acid solution decomposes into water and a small amount of salt after decomposition, with no residue, no toxicity, and no irritation. It is harmless to the human body and the environment and is a green and environmentally friendly disinfectant.

(III) Low cost


Using a hypochlorous acid generator, only salt and water need to be purchased as raw materials, and the cost is relatively low. Moreover, the equipment has a long service life and low maintenance cost.

(IV) On-site production and convenient use


Hypochlorous acid solution can be produced on-site at any time as needed, without the need for storage and transportation, avoiding the risk of deterioration and leakage of disinfectants during storage and transportation, and is more convenient and flexible to use.

ModelGBW-60L-HCLOGBA-200L-HCLOGBA-400L-HCLOGBA-600L-HCLOGBA-800L-HCLO
Dimension of Host Machine470*360*200mmL660*W600*H1560mmL860*W750*H1760mmL1100*W900*H1860mmL1200*W900*H1860mm
Control modeManual ControlAuto ControlAuto ControlAuto ControlAuto Control
Touch screen equippedNoYesYesYesYes
Running time8 hours per day24hour continous working24hour continous working24hour continous working24hour continous working
HOCl output60L/h200L/h400L/h600L/h800L/h
HOCl concentration200ppm200ppm200ppm200ppm200ppm
HOCL PH range3.0~8.03.0~8.03.0~8.03.0~8.03.0~8.0
HOCL ORP range800~1100mV800~1100mV800~1100mV800~1100mV800~1100mV
Alkaline output20L/h70L/h140L/h210L/h280L/h
Alkaline Component0.05~0.1% NaOH0.05~0.1% NaOH0.05~0.1% NaOH0.05~0.1% NaOH0.05~0.1% NaOH
Alkaline PH range10~1210~1210~1210~1210~12
Power requirement1 kw5kw8kw11kw15kw
Voltage220V/50hz single phase220V/50hz single phase220V/50hz single phase220V/50hz single phase220V/50hz single phase
Feed Water RequirementRO water, TDS<20RO water, TDS<20RO water, TDS<20RO water, TDS<20RO water, TDS<20
Feed Water Flow100L/h300L/h600L/h1000L/h1200L/h
AdditivesSoftened saltSoftened saltSoftened saltSoftened saltSoftened salt
Brine concentration of anolyte3~5 g/L3~5 g/L3~5 g/L3~5 g/L3~5 g/L
Number of Cell1 pcs2 pcs4 pcs6 pcs8 pcs
Cell typeMembrane cellMembrane cellMembrane cellMembrane cellMembrane cell
Adjustable ControlFlow adjust, PH adjust, HOCl concentration adjustFlow adjust, PH adjust, Conductivity adjust, Current adjust, HOCl concentration adjustFlow adjust, PH adjust, Conductivity adjust, Current adjust, HOCl concentration adjustFlow adjust, PH adjust, Conductivity adjust, Current adjust, HOCl concentration adjustFlow adjust, PH adjust, Conductivity adjust, Current adjust, HOCl concentration adjust
Detection UnitVoltage/current detectionVoltage/current detection, PH, ORP detection, conductivity detection, Component status detectionVoltage/current detection, PH, ORP detection, conductivity detection, Component status detectionVoltage/current detection, PH, ORP detection, conductivity detection, Component status detectionVoltage/current detection, PH, ORP detection, conductivity detection, Component status detection
Acid Cleaning modeManualAutoAutoAutoAuto
Salt Consumption5g per Liter HOCl5g per Liter HOCl5g per Liter HOCl5g per Liter HOCl5g per Liter HOCl
Water Consumption1.35L per Liter HOCl1.35L per Liter HOCl1.35L per Liter HOCl1.35L per Liter HOCl1.35L per Liter HOCl
Power Consumption8 watt per liter HOCl8 watt per liter HOCl8 watt per liter HOCl8 watt per liter HOCl8 watt per liter HOCl

China 500L/h 800ppm Acidic Electrolyzed water machine for Chicken Farm supplier

500L/h 800ppm Acidic Electrolyzed water machine for Chicken Farm

Inquiry Cart 0