Flexible Copper Conductor Welding Power Cable Single Or Double Insulation

Brand Name:CN CABLE
Certification:IS
Model Number:WELDING CABLE
Minimum Order Quantity:1000meters
Delivery Time:20days after payment
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Active Member
Location: Zhengzhou Henan China
Address: No.80 Dianchang Road,High-Tech Industrial Zone, Zhengzhou,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

Welding Cable with EPR/NBR rubber jacket, according to IS 6830/84 equivalents to BS 6899 and DIN VDE 0282 part 6


- Conductor resistance
according to IS: 8130/84 equivalent to HD 383 cl. 6.

- Conductor resistance factor

at +20˚ C – see technical information

- Temperature range
flexing -25˚ C to +80˚ C
fixed installation -40˚ C to +80˚ C
- Admissible working temperature

at conductor +85˚

- Nominal voltage 100V

- Test voltage 1000V


Cable structure :

- Plain copper conductors, extra fine stranded to IS 8130/84 equivalents to BS 6360, IEC 60228 & HD 383.

- tape used as separator over the conductor.

- EPR/NBR outer rubber jacket, as per type SE-3.
- Outer sheathing black

- With marking of brand name and cross section.

- Testing of cable carried out as per IS 9857/90 equivalents to BS 638 part 4.

- Heat, oil and fire retardant cable.


Application
- Rubber insulated flexible welding cable are used to connect Welding Machine & for better welding proficiency.

- Used in Automobile industries, Shipbuilding, Transport, Steel Plans, Railways, Refineries, Oil fields, Automatic Welding Robots, Construction, Coal Mines etc.

- The robust construction makes these cables resistance to both cold & heat as well as to flames.

- They are suitable for use in open spaces and in dry and damp conditions.


Welding Cable with standard flexibility, bending radius : approx. 15 x CableØ

Cross-Sec
(Sq.mm)
Current Rating At a Max Duty CycleNo. of x Single
Wires WireØ
(mm)
Radial thickness
of sheathing
(mm)
Outer Diameter
min ~ max
(mm)
Max Resistance
@ 20˚C
(ohm/km)
AWG
No.
Permanent
100%
(Amps)
85%
(Amps)
60%
(Amps)
30%
(Amps)
1x16513 x 0.22.08.7 ~ 10.71.2101351461742466
1x25783 x 0.22.010.5 ~ 12.50.7801771922283434
1x35497 x 0.32.012.1 ~ 14.10.5542212402854032
1x50702 x 0.32.214.0 ~ 16.00.3862793033605091
1x70999 x 0.32.416.2 ~ 18.20.2723523824546432/0
1x951302 x 0.32.618.9 ~ 20.90.2064244605477743/0
1x1201702 x 0.32.820.2 ~ 23.20.1614915256018144/0
1x1502121 x 0.33.022.4 ~ 26.40.129568614708921300Kcmil



Welding Cable with extreme high flexibility, bending radius : approx. 12 x CableØ :

Cross-Sec
(Sq.mm)
No. of x Single
Wires WireØ
(mm)
Radial thickness
of sheathing
(mm)
Outer Diameter
min ~ max
(mm)
Max
Resistance
@ 20˚C
(ohm/km)
AWG
No.
1x16513 x 0.22.08.7 ~ 10.71.2106
1x25783 x 0.22.010.5 ~ 12.50.7804
1x351120 x 0.22.012.1 ~ 14.10.5542
1x501600 x 0.22.214.0 ~ 16.00.3861
1x702240 x 0.22.416.2 ~ 18.20.2722/0
1x953024 x 0.22.618.9 ~ 20.90.2063/0

Safety Requirements
1. Coiled welding cable must always be spread out before using to avoid overheating in use.
2. Cables must not be spliced within 10 feet of the holder.
3. Welding cable must never be coiled or looped around the body of the worker.
4. Cables with damaged insulation must be replaced.
5. Welding cable must only be joined through the means of recommended connections.