Fluke 1587FC Digital Clamp Meter Multimeter For Insulation Test 1587MTD

Brand Name:Fluke
Certification:CE
Model Number:Fluke1577 1587 1587FC 1587MTD
Minimum Order Quantity:1 PCS
Delivery Time:2-7 days
Payment Terms:T/T, , Western Union,Paypal,, MoneyGram,, L/C
Contact Now

Add to Cart

Verified Supplier
Address: Liushi Town,Yueqing City,Zhejiang Province,China
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Fluke 1587FC 1587MTD Digital Clamp Meter Multimeter Insulation Test FLUKE Insulation Multimeter

Product Description

Two powerful tools in one:

The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured,
true-rms digital multimeter in a single compact, handheld unit, which provides maximum versatility for both troubleshooting and
preventative maintenance. Like other tools that you have come to expect from Fluke, the 1587 and 1577 are rugged, reliable and easy to use. Whether you work on motors, generators, cables or switch-gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks.


Overview

• Large display with backlight
• Insulation test (1587: 0.01 MW to 2 GW)
(1577: 0.1 MW to 600 MW)
• Insulation test voltages (1587: 50 V, 100 V, 250 V,
500 V, 1000 V),(1577: 500 V, 1000 V) for many
applications
• Live circuit detection prevents insulation test if voltage
> 30 V is detected for added user protection
• Auto-discharge of capacitive voltage for added user
protection
• AC/DC voltage, DC milliVolts, AC/DC milliamps,
Resistance (W), Continuity
• Filter for motor drive measurements (1587 only)

• Capacitance, diode test, temperature, Min/Max,
frequency (Hz) (1587 only)
• Auto power off to save battery power
• CAT III 1000 V, CAT IV 600 V measurement category
• Included accessories: Remote probe, test leads and probes, alligator clips, (K-type thermocouple,1587 only)
• Accepts optional Fluke TPAK™ magnetic hanging system to free your hands for other work
• Rugged, utility hard case allows you to bring everything you need for the job
• Three year warranty

Specifications Of Fluke 1587FC Insulation Multimeter

Electrical Specifications
AC voltage measurement
Range
600.0 mVResolution0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
6.000 VResolution0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
60.00 VResolution0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
600.0 VResolution0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹
1000 VResolution1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage
Range
600.0 mVResolution0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
6.000 VResolution0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
60.00 VResolution0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
600.0 VResolution0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
1000 VResolution1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
DC Voltage Measurement
RangeResolutionAccuracy ±(% of Rdg + Counts)
6.000 V dc0.001 V±(0.09% + 2)
60.00 V dc0.01 V±(0.09% + 2)
600.0 V dc0.1 V±(0.09% + 2)
1000 V dc1 V±(0.09% + 2)
Input impedance10 MΩ (nominal), <100 pF
Normal mode rejection ratio>60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio>120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement
RangeResolutionAccuracy ±(% of Rdg + Counts)
600.0 mVdc0.1 mV±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range400 mA
Resolution0.1 mA
Accuracy ±(% of Rdg+Counts)±(1.5% + 2)¹
Burden voltage (Typical)2 mV/mA
Range60 mA
Resolution0.01 mA
Accuracy ±(% of Rdg+Counts)±(1.5% + 2)¹
Burden voltage (Typical)2 mV/mA
DC
Range400 mA
Resolution0.1 mA
Accuracy ±(% of Rdg+Counts)±(0.2% + 2)
Burden voltage (Typical)2 mV/mA
Range60 mA
Resolution0.01 mA
Accuracy ±(% of Rdg+Counts)±(0.2% + 2)
Burden voltage (Typical)2 mV/mA
Overload600 mA for 2 minutes maximum
Fuse protection for mA input0.44 mA, 1000 V, IR 10 kA
AC conversionInputs are ac-coupled and calibrated to the rms value of sine wave input

China Fluke 1587FC Digital Clamp Meter Multimeter For Insulation Test 1587MTD supplier

Fluke 1587FC Digital Clamp Meter Multimeter For Insulation Test 1587MTD

Inquiry Cart 0