Wall Mounted Residual Chlorine Meter with IP65 and IP68 Protection and 4-20mA Output for Free Chlorine Measurement

Brand Name:KACISE
Certification:CE
Model Number:KSM-150B
Minimum Order Quantity:1PCS
Delivery Time:5-8 work days
Payment Terms:MoneyGram,Western Union,T/T,D/P,D/A,L/C
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

Product introduction

This product is a new generation of intelligent water quality detector independently developed by our company, which adopts advanced non-membrane constant voltage sensor, no need to replace the diaphragm and agent, high sensitivity, rapid signal response, accurate measurement, stable performance and simple maintenance. With English menu operation, high stability, superior repeatability, multi-functionality, etc., it can accurately measure the free chlorine value in solution. It is used for continuous monitoring and control of free chlorine content in water solution.

Widely used in: water treatment plants, canning plants, drinking water distribution networks, swimming pools, cooling and circulating water, water treatment projects, etc.

Main Feature

² Adopting advanced non-membrane type constant voltage sensor, no need to replace the diaphragm and agent, high sensitivity, rapid signal response, accurate measurement, stable performance, stable zero position, simple maintenance, more suitable for low range occasions.

² Large screen dot-matrix LCD display. Chinese and English menu operation.

² Manual temperature compensation.

² Communication function (optional): With RS-485 communication interface (partially compatible with MODBUS protocol)

² Able to Restore factory settings.

² Watchdog function: ensure that the meter will not crash.

² Power-off protection> 10 years.

² Protection level: IP65(controller), IP68(CL electrode)

Technical indicators

(1) Measuring Range: free chlorine 0-20.00mg/L

(2) Resolution: 0.01mg/L

(3) Accuracy: ±1%FS

(4) Alarm output: high or low alarm outputs correspond to any parameters.

(5) Signal isolation output: 420mA isolated protection output

(6) Working conditions: temperature of 0-60 , relative humidity≤90%

(7) Output load: load <500Ω(4-20mA)

(8) Working voltage: AC 220V±10%.

(9) Size: 218 × 183 × 126mm

(10) Installation: wall-mounted

(11) Weight: 1.5Kg (without electrodes)

(12) Protection level: IP65(controller), IP68(CL electrode)

Instrument installation

Host installation

The instrument should be installed in a clean, dry, well-ventilated location without vibration, and there should be no corrosive gas around it.


The installation method is wall-mounted installation. First, fix the screws on the wall according to the position of the installation hole of the instrument, and then install it firmly.

Electrode installation

The electrode must be installed in the constant current electrode seat hole of the constant current device if the constant flow device continuously passes water, and ensure that the electrode is always immersed in the water. If the constant current device loses water for a long time, please Take out the sensor and cover it with the original rubber sheath. The rubber sheath must ensure the protective liquid. The specific installation is as follows.

A. Taking out the electrode and carefully push the rubber sleeve of the electrode with your fingernail (note: do not twist it by hand to avoid damaging the electrode) until the rubber sleeve is fully pushed out. Note: If you try to install it temporarily, it is best to save the rubber sleeve and the protective liquid in the sleeve, so that after the test installation, the sampling electrode can cover the rubber sleeve and the protective liquid back to the electrode. The protective solution is slightly corrosive, and if it gets on the skin, it will be rinsed off with water.B. Inserting the electrode into the constant hole of the constant current device (close to the hole of the water outlet). Be careful not to damage the glass head on the top of the sensor. Before installation, please make sure to use the raw material tape (threaded part) for waterproof sealing before installation. The measured media should be kept at a constant flow rate and constant, suggested water flow is 15~30 cm3/s.

Installation method:

China Wall Mounted Residual Chlorine Meter with IP65 and IP68 Protection and 4-20mA Output for Free Chlorine Measurement supplier