Non-reagent Type Free Available Chlorine Sensor with Rotating Electrode for Continuous Online Measurement

Brand Name:Yokogawa
Model Number:FC800D
Minimum Order Quantity:1pcs
Delivery Time:5-8 work days
Payment Terms:MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability:1000 Piece/Pieces per Week negotiable
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

Providing reliable chlorine measurements in Water Treatment Plants since 1959
No.1 Process analyzer supplier to Japanese market*

"Reliable Chlorine monitoring and minimize Chlorine injection"

"Continuous automatic cleaning and achieved less maintenance time "

"Maintenance remotely for efficient process management"

Many of our customers face these challenges - Yokogawa Chlorine Analyzers resolve them.

The FC800D non-reagent free available chlorine analyzer adopts the polarographic method, and a unique rotating electrode provides a continuous online measurement of free available chlorine concentration.

The FC800D is part of the SENCOM4.0 platform family and can connect to the FLXA402T. Thanks to a smart unit equipped behind the electrode unit, FC800D gives you more insight into the ordinary operation.

The FC800D is suitable for water distribution measurements at pumping stations, water delivery points, schools, and public facilities.
*Based on a Yokogawa survey in 2019

Features

Reagent free measurement, Reduced maintenance due to rotating electrode

  • Amperometric measurement of free chlorine (polarographic method)
  • Measure Free chlorine continuously without reagent
  • Unique rotation electrode method keeps sensor clean and reduces maintenance cycle
  • Easy maintenance structure, modularized motor unit and diagnostics functions strongly support regular maintenance
  • FC800D is equipped with Manual calibration and Auto Calibration, 2 points correction, Basic (reference) sensitivity calibration, and circuit open Zero calibration
  • Remote range switching is available

Configuration

Unique rotating electrode method keeps sensor clean

Continuous automatic cleaning with beads realizes contamination-resistant and stable measurement
You can reduce maintenance time dramatically thanks to easy maintenance structures.

  • Smart unit: Built-in Main board
  • Electrode Unit: Built-in Motor, Rotating contact
  • Beads Case: Houses cleaning beads
  • Needle valve for flow rate adjustment
  • Rotating electrode: Rotating electrode with beads keep the surface polished. This keeps the measurement electrode contaminant free providing long term stability.
  • Reference electrode: Built-in temperature sensor for temperature compensation

Applications

Each process at treatment plant: from reservoir to treated water, distribution system

Water Purification Treatment

  • Stabilization
  • Flocculation
  • Settling Basins
  • Chlorination
  • Clean water reservoir
  • Distributing pump
  • Distribution tank & Piping


Specifications

Measured ObjectFree chlorine in tap water
Measuring SystemAmperometric method (Polarographic method) using rotating electrode
Measuring RangeFree chlorie 0-1 to 0-3 mg/L(-F1), Combined chlorine insentive version 0-1 to 0-3 mg/L(-C1),
Free chlorie 0-5 mg/L (-F2) (*), Free chlorie 0-10 mg/L( -F3) (*)
(*) As for "-F2" and "-F3", please refer to the General Specifications.
Sample Condition (-F1, -C1)Temperature0 to 50°C (Temperature compensation is effective within 0 to 40°C)
pHNo pH fluctuation
pH6.5 to 7.5
(pH6.0 to 8.0 :Chlorine value 1mg/L(-F1))
ConductivityNo conductivity fluctuation
100 to 300 μS/cm
(100 to 500 μS/cm :Chlorine value 1mg/L(-F1))
Flow Rate0.1- 2.5 L/min
Pressure1-150 kPa
SS (Suspended Solid)under 10 mg/L
Power Supply100 to 240 V DC, 50/60 Hz
Digital CommunicationModbus TCP/IP, Modbus RTU
InstallationIndoor (Outdoor use requires protection against rain.Direct sunlight must be avoided.)


Performance (-F1 and -C1)

Linearity±5% of reading or ±0.05mg/L whichever is greater
Repeatability±1% of reading or ±0.01mg/L whichever is greater

* As for "-F2" and "-F3", please refer to the General Specifications.


China Non-reagent Type Free Available Chlorine Sensor with Rotating Electrode for Continuous Online Measurement supplier

Non-reagent Type Free Available Chlorine Sensor with Rotating Electrode for Continuous Online Measurement

Inquiry Cart 0