Optical Dissolved Oxygen Sensor with ± 0.05 mg/L + 1% Accuracy and 90% Response Time < 90 Seconds for Fast Response Water Quality Monitoring

Brand Name:Yokogawa
Model Number:DO71/DO72
Minimum Order Quantity:1pcs
Delivery Time:5-8 work days
Payment Terms:MoneyGram,Western Union,T/T,D/P,L/C,D/A
Supply Ability:1000 Piece/Pieces per Week negotiable
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

See the light by using precise low maintenance SMART optical dissolved oxygen technology

The Yokogawa SMART optical dissolved oxygen sensors DO71 and DO72 have a high degree of durability and stability and require limited maintenance.
Key features of the smart optical DO sensors are fast response time, no warm-up time, and exceptional long-term stability. Qualities that support a high degree of process and cost optimization.

Because of their flat sensor surface and stainless-steel body, the DO71 and DO72 SMART sensors are robust and easy to clean. They are suitable for measurements ranging from low ppb levels to saturated oxygen levels in the water. Ideal for W&WW applications or industrial oxygen monitoring when the sensor needs to be able to withstand challenging measurement environments.

The DO71 and DO72 are digital dissolved oxygen SMART sensors with RS-485-based communication. This feature enables easy calibration in the field, workshop, or laboratory when using the FREE commissioning software "SENCOM ct”.

The sensors' smart functionality enables communication with any other Modbus HOST, such as a PLC, data acquisition system, or other intelligent device, in addition to the Yokogawa FLXA402 analyzer series.

Features

Easy to clean and long-time stability for a long time

The DO71/DO72 use a fluorescence phase-shift method, which is less susceptible to contamination than the fluorescence intensity method and allows more accurate measurement.

Excellent maintainability

Maintenance is done only by replacing the sensor cap at the tip, and it can be easily replaced without using any tools.
Because of no electrolyte, it can be used continuously for a long time without maintenance.

Supports a wide range of measurement environments

DO71 and DO72-W for 0 to 22.5 mg/L can be used for wide range applications such as waste water treatment and process control, and DO72-T for 0 to 2 mg/L can be used for low concentration applications such as SWAS. In addition, a variety of cleaning options are available and it is suitable for difficult applications and for strict water quality control.

Simple measurement system and easy installation

The 4-wire liquid analyzer FLXA402 can connect a pH sensor, conductivity sensor, galvanic or polarographic method dissolved oxygen sensor to the second module of FLXA. You can easily customize analyzer according to your process requirements.

Control delicate process measurement processes

With a 90% response time of less than 90 seconds, it can quickly follow the oxygen concentration change of the process.



ParameterDO71
Sensor typeOptical Dissolved oxygen sensor
Measuring range0 to 22.5 mg/L O₂
Accuracy± 0.05 mg/L + 1% of reading
Repeatability± 0.05 mg/L + 0.5% of reading
Temperature accuracy≤ 1.0 °C
Operating temperature0 to 50 °C
Mechanical pressure0 to 3 Bar(g) (overpressure); 0 to 0.999 Barg (underpressure)
Response time t90≤ 90 sec
Insertion lengths106 mm
Area classificationGeneral purpose
Connection typePermanent cable with 3, 5, 10 or 20m length


ParameterDO72-W
Sensor typeWide measuring range optical dissolved oxygen sensor
Measuring range0 – 22.5 mg/L O₂
Accuracy± 0.05 mg/L + 1% of reading
Repeatability± 0.05 mg/L + 0.5% of reading
Temperature accuracy≤ 1.0 °C
Insertion lengths120 mm
Area classificationGeneral purpose
Connection typeVariPin connector
Operating temperature0 °C to +50 °C
Pressure0-12 Barg (overpressure); 0-0.990 Barg (underpressure)
Response time t90≤ 120 sec


ParameterDO72-T
Sensor typeTrace measuring range optical dissolved oxygen sensor
Measuring range0 – 2 mg/L O₂
Accuracy± 3 ppb + 3% of reading
Repeatability± 3 ppb + 3% of reading
Temperature accuracy≤ 1.0 °C
Insertion lengths120 mm
Area classificationGeneral purpose
Connection typeVariPin connector
Operating temperature0 °C to +50 °C
Pressure0-12 Barg (overpressure); 0-0.990 Barg (underpressure)
Response time t90≤ 120 sec