KGD-WQ-509Engine Exhaust Particle Number Analysis System

Product Introduction

The Engine Exhaust Particle Number Analysis System can continuously measure the number concentration of solid particles in engine exhaust gas online. It can be combined with a full - flow dilution system or a partial - flow dilution system and is used for engine/vehicle certification tests in accordance with the latest regulations. It can also directly measure exhaust gas from the exhaust pipe for research and development tests of engines or after - treatment devices.

Product Features

  • High - precision primary and secondary dilution
  • High - performance VPR (Volatile Particle Remover) device
  • High - precision CPC (Condensation Particle Counter)
  • Minimum particle size limit can be extended to 10nm

Technical Parameters

ParameterHeavy - duty Vehicles: Euro VI, China VI;Heavy - duty Vehicles: Euro 7
Compliance StandardNon - Road Mobile Machinery: Stage V
Minimum Particle Size Limit (Counting Efficiency)23 nm (50% ± 12%)10 nm (65% ± 15%)
Minimum Particle Size Limit (Counting Efficiency)41 nm (>90%)15 nm (>90%)
Measurement PrincipleCondensation Particle CountingCondensation Particle Counting
CPC Measurement Range0 - 100000 #/cm³0 - 100000 #/cm³
CPC Measurement Precision≤ ±10%≤ ±10%
Primary Dilution Ratio1010
Secondary Dilution Ratio10-3010-30
Precision of Total Dilution Ratio≤ ±10% of the set value≤ ±10% of the set value
VPR Removal Efficiency>99.0% (C40)>99.0% (C40)
Response TimeT90 < 5sT90 < 5s
Operating EnvironmentAmbient temperature: 5 - 35°C; Relative humidity: ≤ 80%RHAmbient temperature: 5 - 35°C; Relative humidity: ≤ 80%RH