KGD WQ 508 Partial Flow Particulate Matter Sampling System With Dilution Exhaust Gas Flow Control Range 35 100 SLM

Brand Name:KACISE
Certification:CE
Model Number:KGD-WQ-508
Minimum Order Quantity:1PCS
Delivery Time:5-8 work days
Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

KGD - WQ - 508 Partial - flow Particulate Matter Sampling System

Product Introduction

The KGD - WQ - 508 Partial - flow Particulate Matter Sampling System is an automated device that mixes clean air with a small amount of raw exhaust gas sampling airflow to form diluted exhaust gas, and collects particulate matter in the diluted exhaust gas through a filter paper. This device uses a high - frequency flow control strategy to quickly and accurately control the sampling flow rate, making it change proportionally and synchronously with the total flow rate of the engine's raw exhaust gas. Thus, it can quantitatively analyze the PM concentration of exhaust gas particulate matter under the transient operating conditions of the engine.

Product Features

  • Has two operating modes: proportional dilution and fixed - ratio dilution.
  • Has an automatic filter paper switching function.
  • Has a one - key automatic operation function for flow calibration and linearity check.
  • Has a constant - temperature control system for dilution air and diluted exhaust gas.

Technical Parameters

ParameterDetails
Applicable Engine RangeEngines of any size, at any speed, and with exhaust pipes of various specifications
Sampling Flow Measurement Accuracy≤ ±4% (Dilution ratio ≤ 15:1)
Dilution Air Flow Control Range35 - 100 SLM
Dilution Exhaust Gas Flow Control Range35 - 100 SLM
Dilution Air Flow Control Accuracy≤ ±1%
Dilution Exhaust Gas Flow Control Accuracy≤ ±1%
Filter Paper Size47mm diameter or 70mm
Pre - Heated Temperature of Filter Paper47 - 55°C
Gas Flow Rate through Filter Paper35 - 100 cm/s
China KGD WQ 508 Partial Flow Particulate Matter Sampling System With Dilution Exhaust Gas Flow Control Range 35 100 SLM supplier

KGD WQ 508 Partial Flow Particulate Matter Sampling System With Dilution Exhaust Gas Flow Control Range 35 100 SLM