Mainstream End Tidal Carbon Dioxide Sensor KGD - 412 for Measuring End - Tidal CO₂ Concentration

Brand Name:KACISE
Certification:CE
Model Number:KGD-412
Minimum Order Quantity:1PCS
Delivery Time:5-8 work days
Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

Mainstream End - Tidal Carbon Dioxide Sensor KGD - 412 for Measuring End - Tidal CO₂ Concentration

Product Introduction

The KACISE end - tidal ETCO₂ sensor KGD - 412 is a mainstream ETCO₂ sensor module designed based on the non - dispersive infrared detection principle, used for measuring the end - tidal CO₂ concentration. The KGD - 412 can be applied to monitors, medical ventilators, and anesthesia machines. It has the advantages of accurate and reliable readings, perfect waveforms, compact appearance, and flexible installation.

Product Features

  • Independent NDIR sensor technology
  • 100Hz high - frequency sampling for fast response
  • Adopts blackbody light source, with long service life and good stability
  • Interface and communication protocol that can match mainstream monitors in the market
  • Meets the requirements of standards such as EN IEC 55014 - 1:2021 and EN IEC 61000 - 3 - 2:2019

Technical Parameters

ItemsDetails
Detection PrincipleNon - Dispersive Infrared Technology (NDIR)
Data OutputCO₂ concentration (mmHg), end - tidal CO₂, inhaled CO₂, respiratory rate
Detection Range0 - 150mmHg
Resolution0.1mmHg
Detection Accuracy0 - 40mmHg: ±2mmHg
41 - 70mmHg: True value ±5%
71 - 100mmHg: True value ±8%
100 - 150mmHg: True value ±10%
Respiratory Rate Range0 - 150BPM
Respiratory Rate Accuracy±1 breath
StabilityShort - term drift: not exceeding 0.8mmHg (4H)
Long - term drift: maintaining accuracy specifications within 120H
Input Voltage5.00V (±5%)
Average Current<120mA
Peak Current<250mA
Initialization TimeDisplay within 15s, full specification within 2min (25°C)
CompensationAir pressure: 400 mmHg - 850 mmHg
Working Temperature and HumidityOperation: 0°C - 45°C, 10 - 90% RH, non - condensing
Storage: -40°C - 70°C, < 90% RH, non - condensing
Data CommunicationRS232
Serial Port19200 - N - 8 - 1
Dimensions22 mm * 23 mm * 36mm
China Mainstream End Tidal Carbon Dioxide Sensor KGD - 412 for Measuring End - Tidal CO₂ Concentration supplier

Mainstream End Tidal Carbon Dioxide Sensor KGD - 412 for Measuring End - Tidal CO₂ Concentration

Inquiry Cart 0