250VAC/10A Relay Capacity KSF6-O2-201 System Control Cabinet with Resistive Touch Technology

Brand Name:KACISE
Certification:CE
Model Number:KSF6-O2-201
Minimum Order Quantity:1PCS
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

KSF6-O2-201 System Control Cabinet


Product Introduction

The KSF6-O2-201 system control cabinet is a central control device that can monitor in real time the concentrations of sulfur hexafluoride (SF6) and oxygen in the air, as well as the environmental temperature and humidity in the working places of indoor electrical equipment. The device is equipped with a 7-inch true-color touch display screen to show the concentration values of SF6 and O2 at each node. When the values exceed the alarm set values, audible and visual alarms will be triggered. The device has a human body infrared monitoring function. It can upload real-time detection data records and alarm records online through RS485 communication and WIFI communication functions. It is widely used in fields such as the gas analysis industry, industrial process control, environmental detection, and power plants and substations.

Product Features

  • 7-inch industrial true-color touch display screen
  • Fast response time
  • Real human voice broadcast
  • Audible and visual alarm functions
  • Explosion-proof design
  • Can be linked with fans/exhaust fans
  • Automatic time calibration
  • Wireless/wired communication capabilities
  • Equipped with a PIR infrared monitoring function, supporting human body induction, and the induction range is not less than 3M
  • Capable of historical data recording and querying, automatic recording of alarm events, and failure records, and the data will not be lost in case of power failure
  • High reliability and long service life (>10 years)
  • Small size, compact structure, and easy to install

Technical Parameters

Touch ModeResistive touch
Resolution800*480
Alarm ModeReal human voice broadcast/audible and visual alarm
Fan Starting PointSF6 concentration ≧ 1000ppm; O2 concentration ≦ 19.6%vol
Fan Starting ConditionsManual forced start; 2. SF6 over-limit or oxygen deficiency; 3. Timed exhaust
Relay Capacity250VAC/10A
Historical Data Storage TimeAlarm values are stored for 10 years
Driving Capacity32 detection units
Output ModeRS485 communication; 2. WIFI communication
Communication Distance1000m
Human Body Infrared Detection Distance≥3m
Dielectric Withstanding Voltage1500VAC (between the power supply and the ground)
Product Dimensions378244107mm
Product WeightTo be determined (TBD)
Designed Service Life>10 years
IP Protection RatingIP54 (can be customized according to actual applications)
Product StandardDL/T 1555-2016; DL/T 639; JB/T 10893
Operating Conditions-20 - +50℃; 0 - 90%RH (non-condensing)
Testing Environment0- +40℃; 0 - 85%RH (non-condensing)
Operating Air Pressure86kPa - 106kPa
Applicable PlacesIndoor
Power Supply VoltageAC220V±10% (50HZ±1%)
Operating Frequency50HZ
Rated Power<15W