NMP Gas Leak Alarm KGD-GAS-203


Product Introduction

The NMP Gas Leak Alarm KGD-GAS-203 is a high-performance NMP gas leak alarm independently developed by KACISE based on the non-dispersive infrared (NDIR) principle. It is suitable for detecting the gas concentration at the center of drying equipment and exhaust pipes. The sampling instrument body and the display part adopt an integrated explosion-proof structure design, which is convenient for installation and disassembly. At the same time, this instrument has the characteristics of automatic calibration, long-term maintenance-free operation, and a long service life. It has the functions of industrial 4-20mA current output, RS485 external communication, and alarm output when the concentration exceeds the limit, and can be applied to complex and harsh high-temperature industrial environments.

Product Features

  • Detects high-boiling-point NMP solvent
  • Can operate in a high-temperature environment of 0-160°C
  • Direct insertion into the furnace to accurately detect the concentration at the center of the equipment
  • Adopts a pressure-resistant explosion-proof structure, meeting the explosion-proof grade of Ex db IIC T3 Gb
  • Integrated design, easy to install

Technical Parameters

Detection Gas ObjectNMP (n-methyl-2-pyrrolidone)
Concentration Display7-segment LED (4 digits)
Detection Range0-100%LEL
Display Resolution0.5%LEL
Sampling MethodDifferential pressure intake mode inside the furnace
Alarm Set Value15%LEL~50%LEL (default is 25%LEL, can be set)
External OutputGas concentration signal/Alarm contact
Communication MethodDC4~20mA (resistive load below 300Ω), RS485 (default baud rate is 9600)
Alarm Precision±5%LEL@15%LEL~50%LEL
Alarm DelayT90<30s@15%LEL~50%LEL
Alarm Contact Capacity250VAC0.2A/30VDC1.5A (impedance load)
Alarm ActionAutomatic reset
Working Voltage24VDC±10%
Average Working CurrentAverage working current < 1.0A (@25℃, 24VDC)
Preheating Time≤30min
Working TemperatureTemperature of the measured gas: 0~160℃ (usually) Working temperature of the meter head: 0~60℃ (usually)
Working HumidityLess than 95%RH (without condensation)
Service Life10 years
StructureDirect insertion into the furnace
Explosion-proof StructureFlameproof structure
Explosion-proof GradeExdbIICT3Gb
Overall Dimensions/Weight418mm178mm110mm/Approximately 6kg
China NMP Gas Leak Alarm KGD-GAS-203 supplier

NMP Gas Leak Alarm KGD-GAS-203