EcoSulfide H2S Detection Module - A Reliable Alternative to Alphasense

Brand Name:KACISE
Certification:CE
Model Number:KQT-H2S
Minimum Order Quantity:1PCS
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

EcoSulfide H2S Detection Module - A Reliable Alternative to Alphasense

1.Overview

KACISE’s EcoSulfide H2S Detection Module is an eco-friendly, high-performance solution for hydrogen sulfide detection, serving as a reliable alternative to Alphasense. Designed for integration into industrial and environmental systems, it features a wide linear range, high sensitivity (650±200nA/ppm), and excellent repeatability. With a detection range of 0-100ppm and robust anti-interference capabilities, the EcoSulfide module ensures accurate and stable performance in challenging conditions. KACISE’s innovative engineering ensures low power consumption and long service life, making it a sustainable choice for H₂S monitoring in mines, industrial sites, and atmospheric environments.

2. Application Fields

1.Hydrogen sulfide alarm

2.Hydrogen sulfide gas detection in industrial sites

3.Hydrogen sulfide detection in mines

4.Hydrogen sulfide detection in the atmospheric environment

3. Product Features

1.High precision and long service life

2.Fast response speed and quick return to zero

3.Low power consumption and high sensitivity

4.Wide linear range

5.Strong anti - interference ability

6.Excellent repeatability and stability

4. Technical Parameters

ProjectParameter
ModelKQT-H₂S
Detection PrincipleElectrochemical three - electrode
Detected GasH₂S
Detection Range0 - 100PPM
Maximum Load Concentration500PPM
Sensitivity650±200nA/PPM
Zero - point Drift±2PPM
Resolution1PPM
Response TimeT90< 30s
Bias Voltage0
Load Resistance5 - 30Ω
Temperature Range- 30℃ - 50℃
Humidity Range15% RH to 90% RH (no condensation)
Repeatability1% output signal
Long - term Stability< 2% signal / month
LinearityLinear, regression coefficient R² = 0.999
Working Pressure90 to 110 kPa
Shelf Life12 months after delivery
Service Life3 years

China EcoSulfide H2S Detection Module - A Reliable Alternative to Alphasense supplier

EcoSulfide H2S Detection Module - A Reliable Alternative to Alphasense

Inquiry Cart 0