TDLAS200 High-Sensitivity Laser Methane Sensor with 0.5ppm Detection Limit and 0~5000ppm Range for Industrial Safety

Brand Name:KACISE
Certification:CE
Model Number:TDLAS200
Minimum Order Quantity:1PCS
Delivery Time:5-8 work days
Payment Terms:L/C,D/A,D/P,T/T,Western Union,MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

TDLAS200 High-Sensitivity Laser Methane Sensor

1.Introduction


The KACISE TDLAS200 High-Sensitivity Laser Methane Sensor is designed for precise methane detection with unparalleled accuracy. Utilizing Tunable Diode Laser Absorption Spectroscopy (TDLAS) technology, it offers a detection range of 0~5000ppm and a static detection limit of 0.5ppm. Its high sensitivity ensures reliable performance in various environments, with an operating temperature range of -20~50℃. The sensor features a built-in reference cell for automatic calibration and a compact design for easy integration. KACISE combines advanced technology and durability, making this sensor ideal for industrial safety and environmental monitoring.


2.Features

  1. High sensitivity, only responds to the target gas
  2. Built-in reference cell, can be automatically calibrated
  3. Easy to integrate, digital interface directly outputs status and concentration

3.Measuring Principle
"Methane molecules absorb light of a specific wavelength" --Molecular absorption spectrum
"The amount of light absorbed by a transparent medium (methane gas mass) is proportional to the thickness and concentration of the gas mass" --Beer-Lambert's law
According to the above physical principles, a beam of light of a specific wavelength can be used to penetrate the leaking methane gas mass. According to the degree of weakening of the beam, the concentration of methane in the gas mass can be measured, and it only responds to methane (unique selectivity).
Using a detection cell with multiple reflections and allowing the laser to repeatedly pass through the gas being measured can multiply the detection sensitivity.

4.Technical Parameters

Product model

TDLAS200A(Pump)

TDLAS200B(Diffusion)

Detection object

Methane (CH4)

Measurement principle

Laser absorption spectrum (TDLAS)

Static detection limit

0.5ppm@25℃ 5SPS (typical value, please contact us for details)

Volume

53ml

Fastest response time

0.2s

90s

Measurement range

0~5000ppm,0-10000ppm

Measurement deviation

0–200 ppm: ±2 ppm of the true value
200–1000 ppm: ±1% of the true value
1000–5000 ppm: ±2% of the true value
5000–10000 ppm: ±3% of the true value

12hrs drift

+/-1.5ppm

Operating temperature

-20~50℃

Power supply

5-12VDC 1W (typical) 6W (maximum)

Recommended 12V 1A

Dimensions

115×59×38mm

115×59×40mm

Gas inlet/outlet port

Pagoda direct M-5AU-4

*1 Please ensure that the power input voltage of the module is not less than 5V

*2 Pump selection recommendation <500ml/min

5.Dimensions of the detection module

(1) TDLAS200A (Pump) detection module host size 115×59×38mm (excluding cables and gas connectors).

It is recommended to add a 0.45 μm PTFE hydrophobic filter at the gas inlet; connect a pump and a muffler filter at the gas outlet.

(2)TDLAS200B (Diffusion) detection module main unit size 115×59×40mm (excluding cables and gas connectors)


China TDLAS200 High-Sensitivity Laser Methane Sensor with 0.5ppm Detection Limit and 0~5000ppm Range for Industrial Safety supplier

TDLAS200 High-Sensitivity Laser Methane Sensor with 0.5ppm Detection Limit and 0~5000ppm Range for Industrial Safety

Inquiry Cart 0