Dual High Impedance KPH601 Online PH Sensor Differential Amplifier

Brand Name:kacise
Certification:CE
Model Number:KPH601
Minimum Order Quantity:0-100
Delivery Time:3-10days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

KPH601 Online PH Sensor Signal Output: RS-485 (Modbus/RTU Protocol)

1.Temperature compensation

This has to be taken into consideration if pH values obtained by different temperatures are to be compared. Furthermore, the slope depends on the temperature (Nernst equation): E = E0 – 2.303 RT / F  ∆ pH (R,F = constant) Where: E = measured potential E0 = zero point potential ∆pH = difference in pH between outside and inside of the glass membrane F = Faraday constant R = universal gas constant T = temperature Kelvin the slope increases with an increase in temperature (see “5.6 The influence of temperature on pH measurements“ on page 85). The most exact pH value is obtained when the temperature of the calibration and measured solutions are identical. pH Theory Guide 35 METTLER TOLEDO The temperature compensation of the transmitter corrects for this effect. An electrode would have an ideal temperature behavior if its calibration lines (isothermals) intersect at the zero point of the electrode (pH 7 = O mV) at different temperatures (see Figure 18 below). Figure 18 Calibration line and isothermal intersection points. Since the overall potential of the pH electrode is composed of the sum of many single potentials, which all have their respective temperature dependencies, the isothermal intersection hardly ever coincides with the zero point of the electrode (the ideal case would be: 0 mV at pH = 7/25°C). In the last few years, the development of the electrode has concentrated on bringing the isothermal intersection and the zero point as close ­together as possible, since the nearer they are to pH 7 the smaller the error in the temperature compensation. Besides, the measuring error increases with an increasing temperature difference be-tween the calibration and the actuai measuring. As a rule the errors are in the order of 0.1 pH units.
2.Technical Specifications

ModelKPH601
Measuring Range0~14pH
Resolution0.01pH
Accuracy±0.1pH
Working Temperature0~65℃
Working Pressure<0.2MPa
Temperature CompensationAuto temperature compensation (NTC)
Power Supply12~24VDC ±10%
Signal OutputRS-485(Modbus/RTU)
Wetted MaterialPOM
Mounting MethodImmersion mounting, 3/4 NPT thread
Cable Length5 meters, other lengths can be customized
CalibrationTwo-point calibration
Power Consumption<0.3W@12V
Protection GradeIP68

3.Dimensional Drawing


Note:The sensor connector is M16-5 core waterproof joint male head.

4.Installation


Note: The sensor should not be installed upside down or horizontally when installed, at least at an angle of 15 degrees or more.