KFDO601 dissolved oxygen sensor with anti-interference and RS485 interface with precision ±2%

Brand Name:kacise
Certification:CE
Model Number:KFDO601
Minimum Order Quantity:0-100
Delivery Time:3-10days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

KFDO601 Online Fluorescence Dissolved Oxygen No Electrolyte Is Required And Will Not Be Polarized No Oxygen Consumption


1.Dissolved oxygen measurement applications


  • Food and Beverages
  • The pharmaceutical
  • Energy and electricity
  • education
  • The government
  • water
  • Waste water management

2.the Difference of Polarographic probe and optical probe


 Polarographic probeoptical probe
maintenceReplace the electrolyte approximately every 2 months and polish the cathode as needed to clean the probeClean probe, cover and optical window as needed
storageStored in a wet calibration sleeve;For long-term storage, remove the film cover and store in a dry placeStore in a wet calibration sleeve
filmReplace approximately every 2 months as neededno
solutionReplace approximately every 2 months as neededno
Need to preheat(30-60 minutes) if only connected to the meter 
stirneedunnecessary
disturbOzone, sulfides, sulfur dioxide, nitrous oxide and carbon monoxide 

3.Feature


  • No electrolyte is required and will not be polarized.
  • No oxygen consumption, not affected by flow rate.
  • Built-in temperature sensor, automatic temperature compensation.
  • Free from interference by chemicals such as sulfides
  • Small drift, rapid reaction, more accurate measurement.
  • Long service cycle, lower cost of use.
  • Simple replacement of fluorescent cap.
  • Rs-485 interface, Modbus/RTU protocol.
  • Low power consumption,anti-interference.

4.Technical Specifications


ModelKFDO601
Measuring principleFluorescence method
Range ability0~20mg/L (0 ≤ 200% saturation)
Resolution ratio0.01mg/L,0.1℃
Precision±2%F.S.,±0.5℃
Temperature compensationAutomatic temperature compensation(Pt1000)
Output modeRS-485 bus, Modbus-RTU protocol
Working conditions0~45℃,<0.2MPa
Storage temperature-5~65℃
Installation modeImmersion mounting
Cable length5 meters, other lengths customizable
Power dissipation<0.3W@12V
Source12~24VDC ±10%
levels of protectionIP68
CalibrationTwo-point calibration
Fluorescent cap lifeGuaranteed use for one year (under normal use)
Sensor shell materialPOM and 316L stainless steel

5.Dimensional Drawing

Note:The sensor connector is m16-5 core waterproof connector male.

6.Installation


The sensor shall be installed fixedly below the liquid level. The installation and use shall avoid collision or scraping against the surface of the fluorescent film head. The fluorescent film head part shall avoid being attached by the bottom sediment.Remove the rubber cover when use.

Contact Us


Website www.kacise.com
Phone +86-17719566736
Email sales@kacise.com
Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China


China KFDO601 dissolved oxygen sensor with anti-interference and RS485 interface with precision ±2% supplier

KFDO601 dissolved oxygen sensor with anti-interference and RS485 interface with precision ±2%

Inquiry Cart 0