Home /Energy & Mineral Equipment /

Dissolved Oxygen Sensor For Shrimp Farm And Pond Dissolved Oxygen Sensor

Dissolved Oxygen Sensor For Shrimp Farm And Pond Dissolved Oxygen Sensor

Product name:Aquaculture Fluorescence Dissolved Oxygen Sensor
Type:KWS-630
Range:0-20mg/L or 0-200% saturation
Accuracy:±5%
IP Grade:IP68
Sensor Drift:<1% per year
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Dissolved Oxygen Sensor For Shrimp Farm And Pond Dissolved Oxygen Sensor

Introduction
The Kacise KWS-630 fluorescence dissolved oxygen sensor is designed for the aquaculture industry. It has the characteristics of stable online monitoring, and it has excellent characteristics compared with the traditional type sensor. It has no membrane, no need electrolyte, strong anti-interference, no need for frequent calibration, no consumption of oxygen, no flow rate limitation, auto matic temperature and Gas pressure compensation, gast reaction speed, long service life and more economical and convenient, so the fluorescence dissolved oxygen sensor is the best choice for real-time dynamic monitoring of oxygen content in aquaculture.
Features
  • No membrane, no need electrolyte
  • No need to consume oxygen, not affected by flow rate
  • Built-in temperature sensor, automatic temperature compensation
  • Free from chemical interferences such as sulfides
  • Small annual drift, fast response, and more accurate measurement
  • Free of maintenance, longer application cycle and lower cost of use
  • Fluor cap replacement is simple
  • Support RS-485, MODBUS protocol

Technical Specifications
Range
0-20mg/L or 0-200% saturation
Accuracy
±5%
Response Time
3 min
Ip Grade
IP68
Sensor Drift
<1% per year
Operating Temperature
0~50
Temperature Accuracy
Temperature Accuracy
Output
RS485, Modbus
Power SupplyDC6-12V ±5%, current<50mA
Temperature Sensor
NTC
Casing Diameter
22mm
Casing Length
188.3mm
Cable Length
Standard 10m, customizable 5m, 15m and 30m
Fluorescent Cap Lifetime
1 year (under normal use)
Casing Material
POM
Dimensions
China Dissolved Oxygen Sensor For Shrimp Farm And Pond Dissolved Oxygen Sensor supplier

Dissolved Oxygen Sensor For Shrimp Farm And Pond Dissolved Oxygen Sensor

Inquiry Cart 0