KLD800 Series 80G Radar Level Gauge PTFE Antenna Size Small Blind Spot

Brand Name:Kacise
Certification:CE
Model Number:KLD801
Minimum Order Quantity:1
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

KLD800 series 80G Radar Level Gauge small antenna size small blind spot


Introduction


The KLD-80G series radar level gauge is an 80G ultra-high frequency, millimeter-wave radar with a measurement accuracy of up to ±2mm and a minimum blind zone of 0.05m. Lens antenna design, smaller beam angle, more suitable for complex working conditions such as small-diameter tanks and stirring coils in the tank. With stronger penetrability and multiple measurement modes, various antennas can be selected according to different industries and mines to ensure that the radar can also measure stably and accurately under complex conditions such as high temperature, high pressure and high dust.


The high-frequency 80g radar level gauge has the advantages of low maintenance, high performance, high precision, high reliability, and long service life. Compared with contact instruments such as capacitors and weights, it has incomparable advantages. The transmission of microwave signals is not affected by the atmosphere, so it can meet the requirements of harsh environments such as volatile gas, high temperature, high pressure, steam, vacuum and high dust in the process. This product is suitable for harsh environments such as high temperature, high pressure, vacuum, steam, high dust and volatile gas. Continuous measurement of different material levels is possible.


The main technical indicators of the instrument have reached or surpassed similar products at home and abroad, and it is easy to install and debug. It can be used alone or in a network. It can be widely used in metallurgy, building materials, energy, petrochemical, water conservancy, food and other industries.


Feature


⚫ Millimeter wave radar, the measurement accuracy can reach up to ±2mm, and the minimum measurement blind zone is 0.05m.
⚫ The smaller antenna size satisfies the measurement of more working conditions.
⚫ A variety of lens antennas, smaller launch angles, more concentrated energy, stronger echo signals, and higher reliability than other radar products under the same industrial and mining conditions.
⚫ It has stronger penetration and can be used normally in the case of adhesion and condensation.
⚫ The dynamic signal range is larger, and the measurement of low dielectric constant media is more stable.
⚫ Multiple measurement modes, radar response in fast measurement mode

KLD801

Medium: liquid, non-corrosive

Measuring range: 0.05m~10/20/30/60/100m

Process connection: G1½A / 1½NPT thread / flange ≥ DN40

Process temperature: -40~80℃

Process pressure: -0.1~0.3 MPa

Antenna size: 32mm lens antenna

Antenna material: PTFE

Accuracy: ±1mm

Protection class: IP67

Center frequency: 123GHz

Launch angle: 3°

Power supply: Two-wire /DC24V

Four-wire system/DC12~24V

Four-wire system/AC220V

Casing: aluminum/plastic/stainless steel

Signal output: two-wire /4...20mA/HART protocol

Four-wire system: 4...20mA/ RS485 Mo

KLD802

Medium: non-corrosive liquid, slightly corrosive liquid
Measuring range: 0.1m~10/20/30/60/100m
Process connection: flange ≥ DN80
Process temperature: -40~110℃
Process pressure: -0.1~1.6MPa
Antenna size: 32mm lens antenna
Antenna material: PTFE
Accuracy: ±1mm (range below 35m)
±5mm (range between 35m and 100m)
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum/stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire / 4...20mA/ RS485 Modbus

KLD803

Medium: strong corrosive liquid, steam, foam
Measuring range: 0.1m~10/20/30/60/100m
Process connection: flange ≥ DN50
Process temperature: -40~130℃
Process pressure: -0.1~2.5MPa
Antenna size: 34mm lens antenna (according to flange size)
Antenna material: PTFE
Accuracy: ±1mm (range below 35m)
±5mm (range between 35m and 100m)
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum/stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire 4...20mA/ RS485 Modbus

KLD804

Medium: strong corrosive liquid, steam, foam
Measuring range: 0.1m~10/20/30/60/100m
Process connection: flange ≥ DN50
Process temperature: -40~130℃
Process pressure: -0.1~1.0MPa
Antenna size: 76mm lens antenna
Antenna material: PTFE
Accuracy: ±1mm
Protection class: IP67
Center frequency: 80GHz
Launch angle: 2°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum/plastic/stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire 4...20mA/ RS485 Modbus

KLD805

Medium: strong corrosive liquid, steam, foam,
high temperature. and high pressure
Measuring range: 0.1m~10/20/30/60/100m
Process connection: flange ≥ DN80
Process temperature: -40~200℃
Process pressure: -0.1~2.5MPa
Antenna size: 76mm lens antenna (according to flange size)
Antenna material: PTFE/overall filling
Accuracy: ±1mm
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum / plastic / stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire 4...20mA/ RS485 Modbus

KLD806

Medium: solid, storage container, process container,
strong dust application
Measuring range: 0.3m~10/20/30/60/100m
Process connection: flange ≥ DN100
Process temperature: -40~110℃
Process pressure: -0.1~0.3MPa
Antenna size: 76mm lens antenna (purge optional)
Antenna material: PTFE
Accuracy: ±5mm
Protection class: IP67
Center frequency: 80GHz
Launch angle: 3°
Power supply: two-wire /DC24V
four-wire /DC12~24V
four-wire /AC220V
Casing: aluminum/plastic/stainless steel
Signal output: two-wire /4...20mA/HART protocol
four-wire 4...20mA/ RS485 Modbus

Installation Connection Diagram


The maximum installation spool height H max depends on the installation spool diameter D
and the size of the product launch angle.
Too long installation connection will affect the radar performance.


KLD801/02


KLD803/KLD804/KLD805A


KLD806



Power Supply


(4~20) mA/HART(2 wire)The power supply and the output current signal share a two-core shielded cable. Please refer to the technical data for the specific supply voltage range.
(4~20) mA(4 wire/6 wire)The power supply needs to be powered separately, and a four-core shielded cable is used for the power supply and current signal (the current signal and the RS485 interface can be output at the same time, and a six-core shielded cable is required for simultaneous output).
RS485/ModbusThe power supply needs to be powered separately, and a four-core shielded cable is used for power supply and digital signal. (The current signal and the RS485 interface can be output at the same time, and a six-core shielded cable is required for simultaneous output).

Connection



Safety Guide


Please observe the requirements of the local electrical installation regulations!
Follow local regulations for personnel health and safety. All operations on the electrical components of the instrument must be completed by professionals who have received formal training.
Please check the nameplate of the instrument to ensure that the product specification meets your requirements. Please ensure that the power supply voltage is consistent with the requirements on the nameplate of the instrument.



Grade of Protection


This instrument fully meets the requirements of protection class IP66/67, please ensure the waterproofness of the cable sealing head. As shown below:


How to ensure that the installation meets the requirements of IP67:
Make sure the sealing head is not damaged.
Make sure the cable is not damaged.
Please make sure that the cables used meet the requirements of the electrical connection
regulations.
Before entering the electrical interface, bend the cable down to ensure that water will not flow into the housing, see ①
Please tighten the cable gland, see ②
Please plug the unused electrical interface with a blind plug, see ③


Casing Dimension
Unit in mm:


Product Dimension


Unit in mm:


KLD801


KLD802



KLD803



KLD806



KLD804 KLD805


China KLD800 Series 80G Radar Level Gauge PTFE Antenna Size Small Blind Spot supplier

KLD800 Series 80G Radar Level Gauge PTFE Antenna Size Small Blind Spot

Inquiry Cart 0