KSS54X Infrared Hydrocarbon Sensor


1. Overview

KSS54X infrared CH4 sensor module is a gas sensor module using NDIR infrared absorption detection principle, which determines the concentration according to the absorption of infrared gas. KSS54X adopts imported light source, optical cavity with special structure and dual-channel detector to realize space dual optical path reference compensation. Microprocessors perform signal acquisition, processing, and output. KSS54X has good selectivity, high sensitivity, no oxygen dependence, long life, low power consumption; With temperature control and pressure compensation function; It also has UART, 485 output and analog current/voltage output, which is convenient for customers to various applications.


2. Technical Parameters


parametersymbolminimumTypical valuesmaximumunit
Storage TemperatureTstg-20-80°C
Operating TemperatureTA-2060°C
Operating HumidityHA090 non-condensing% RH
Work PressurePA0.81.2atm
Supply VoltageVs111230V
Maximum Operating currentIavg100120150mA

KSS54X infrared CH4 low concentration performance index (typical 0~5000ppm).

indexgasRange/ppmresolutionrelative errorabsolute errorremark
Zero drift

CH4



0~5000



25ppm


±5%FS±100ppmJust meet one of them
Range drift±5%FS±100ppmJust meet one of them
Indication error±5%FS±100ppmJust meet one of them
repeatability±2%FS±50ppmJust meet one of them
T90≤5S(500ml/min)

KSS54X infrared CH4 conventional concentration performance index (0~5% vol).

indexgasRange/volresolutionrelative errorabsolute errorremark
Zero drift

CH4



0~5%



100ppm


±5%FS±500ppmJust meet one of them
Range drift±5%FS±500ppmJust meet one of them
Indication error±5%FS±500ppmJust meet one of them
repeatability±2%FS±300ppmJust meet one of them
T90≤5S(500ml/min)

KSS54X infrared CH4 concentration performance index (typical 0~30% vol)


indexgasRange/volresolutionrelative errorabsolute errorremark
Zero drift

CH4



0~30%



500ppm


±5%FS±3000ppmJust meet one of them
Range drift±5%FS±3000ppmJust meet one of them
Indication error±5%FS±3000ppmJust meet one of them
repeatability±2%FS±1000ppmJust meet one of them
T90≤5S(500ml/min)

KSS54X infrared CH4 full-scale performance index (0~100%vol)


indexgasRange/volresolutionrelative errorabsolute errorremark
Zero drift

CH4



0~100%



1000ppm


±5%FS±5000ppmJust meet one of them
Range drift±5%FS±5000ppmJust meet one of them
Indication error±5%FS±5000ppm Just meet one of them
repeatability±2%FS±5000ppmJust meet one of them
T90≤5S(500ml/min)

3.Structural Dimension Drawing

Unit: mm


KSS54X has three structural sizes, corresponding to 100mm, 150mm, 200mm optical cavity for choice.

100mm cavity structure diagram:


150mm cavity structure diagram:


200mm cavity structure diagram:



Installation instructions

The sensor is installed with a reference structure diagram with a positioning hole spacing and an aperture of 3.5mm.

The wiring socket spacing is 2.54mm.

4.Methods of matters that should be paid attention to in maintenance

The sensor should be calibrated regularly, not more than 3 months is recommended.

Do not use the sensor for a long time in an environment with a high density of dust.

Please use the sensor within the range of the sensor's power supply.

5.Ordering instructions

In order to be able to purchase the specific specifications required, please provide the following information:

1) Sensor name

2) Measure the gas

3) Sensor measurement accuracy and output mode, etc

For example, KSS54X, CH4, 0-5000 ppm


6. Order Information


Order information sheet
KSS54XKSS54X CO2 concentration sensor
xxxxThe sensor measures the range of CO2 concentration in ppm, with a minimum value of 2000 and a maximum value of 50000 ppm.
2000Range 200ppm (default).
10000Range 10000ppm
50000Range 50000ppm
encodeThe reaction speed is divided into two types: fast and slow
SSlow (default).
Qfast
encodeBaud rate selection, support commonly used baud rate 2400 9600 19200 38400bps, 8 bits of data, 1 bit of stop bit, no check bit: Confirm special needs before ordering.
CustomConfirm the baud rate before ordering
24002400bps baud rate
96009600bps baud rate
1920019200bps baud rate
3840038400bps baud rate (default)
encodeSerial port protocol
Modbus-RTUStandard Modbus-RTU protocol (default).
Modbus-ASCIIStandard Modbus-ASCII protocol
Modbus-SelfModbus private protocol
KSS54X-2000-S-38400-Modbus-RTU

7. Contact Details

URL: www.kacise.com

Tel: +86-29-17719566736

Email: sales@kacise.com

Address: Tangyan South Road, Xi'an City, Shaanxi Province, China


Appendix


ShorthandFull name
VOL1% VOL refers to 1% of the volume of a particular gas in air.
PPM1PPM means that the volume of a specific gas in the air accounts for one millionth.
O2Oxygen molecules
LCDLCD display
RS485Asynchronous serial port 485
DCdirect current
ACCommunication
PVCpolyvinyl chloride

China 0~5000ppm hc Gas Detector Sensor Ir Hydrocarbon Gas Sensor supplier

0~5000ppm hc Gas Detector Sensor Ir Hydrocarbon Gas Sensor

Inquiry Cart 0