Add to Cart
Note: Range information is very important
The RS485 ultrasonic level meter is a vital tool in municipal engineering. It utilizes ultrasonic waves to accurately detect liquid levels. With its RS485 interface, it can be easily integrated into existing systems. This meter is highly reliable and precise, enabling continuous monitoring of water, sewage, or other liquids in municipal facilities, ensuring efficient operation and management.
Technical Features:
Structure:
Technical Specifications:
Parameter | Compact type | Split type |
Range | 5m,10m,15m,20m,30m,40m,50m,60m | 5m,10m,15m,20m,30m,40m,50m,60m |
Accuracy | 0.5%~1% | |
Resolution | 3mm or 0.1%(The larger one is effective) | |
Display | English LCD | English LCD |
Analog Output | 4wire 4~20mA/510Ω load 2wire 4~20mA/250Ω load | 4~20mA/510Ω load |
Relay Output | 2 way AC 250V/5A or DC 30V/5A, programmable(optional) | 2 or 4 way AC 250V/ (NO:10A,NC:6A) or DC 24V/ 10A, programmable (optional) |
Power Supply | 24VDC (default) 220V AC+15%@50Hz 12VDC Battery | 24VDC 120mA (default) 220V AC+15%@50Hz 12VDC Battery |
Environment Temperature | Display instrument-20~+60℃, transducer-20~+80℃ | Display instrument -20~+60℃, transducer-20~+80℃ |
Communication | RS485,RS232 (optional) | |
Protocol | Modbus-RTU | |
Protection | Display instrument IP66,transducer IP68 | |
Transducer Cable | no | Default 10m Max. 100m can be ordered (when without electromagnetic interference) |
Transducer Installation | According to range and transducer | According to range and transducer |
Power Consumption | The specific power of split-type is as follows: With only mA output, it is 1.5W/24V (standard); With only RS485 output, it is 0.9W/24V (optional); With both RS485 and mA output, it is 1.6W/24V (optional); Add two relays, the power is increased by 0.8W/24V (optional); The power of 220VAC split-type is 5W/220VAC. The specific power of compact four-wire instrument is as follows: With only mA output, it is 1W/24V (standard); With only RS485 output, it is 0.6W/24V (optional); With both RS485 and mA output, it is 1.1W/24V (optional); Add two relays, the power is increased by 1W/24V (optional); The power of 220VAC compact four-wire instrument is 5W/220VAC. 24V compact two-wire instrument output power and instrument output current value are related: (4mA/0.096W-20mA/0.48W) |
Model Selection:
KUM-A | ||||||
Measurement Range | ||||||
A | 5m | |||||
B | 10m | |||||
C | 15m | |||||
D | 20m | |||||
E | 30m | |||||
F | 40m | |||||
G | 50m | |||||
H | 60m | |||||
Output Signal | ||||||
A | 4-20mA | |||||
Accuracy | ||||||
0.5 | 0.5% | |||||
1.0 | 1% | |||||
Power Supply | ||||||
A | 24Vdc | |||||
B | 11~30Vdc | |||||
Probe Type | ||||||
A | PVDF | |||||
B | Aluminum alloy | |||||
C | ABS | |||||
D | Stainless steel 316L | |||||
E | Teflon | |||||
F | Titanium alloy |
Applications and Installations:
Common problems and solutions guidance during installation
Fault description | cause of issue | Solution |
Meter does not display, does not work | Wrong power supply Wrong wiring | Check whether the DC24v power supply is correct Check whether the wiring is correct |
The instrument has display, does not work | 1. The level gauge is not aligned with the liquid level or material
level 2. The liquid level fluctuates greatly 3. The material surface is extremely uneven 4. The liquid surface has a thicker foam layer 5. The bottom of the container is not flat after the liquid is emptied and the material is emptied 6. Out of measurement range | 1. Adjust the alignment direction of the level gauge, and use a
spirit level to calibrate and add a plastic tube to the container 2. Use a level gauge with a larger range 3. Use a level gauge with a larger range or other measurement methods 4. Naturally resume work after adding liquid or material 5. Use a level gauge with a larger range |
The instrument display is unstable or the measured value has a large deviation | 1. The material level enters the blind spot 2. The distance measurement value is greater than the installation height 3. There is strong electromagnetic interference 4. Objects that block sound waves 5. A metal flange is prepared on the level meter 6. The emitting surface or side of the probe is in contact with metal | 1. Elevate the level meter or prevent the level from being too high 2. Modify the installation height to the correct value 3. The instrument must be connected to the ground, and shield the level gauge 4. Change the installation position or add plastic pipes 5. Switch to plastic flanges 6. Use rubber pads to isolate from metal |
For the container with the installation port or the probe placed in
the round pipe, the length of the flange connection of the 4m, 6m
and 8m type level gauge container should be less than 400mm, and
the length of the 12m level gauge container should be less than
400mm.
150mm, 15m, 20m, 30m level sensor probes should protrude from the
installation port.