high accuracy, low maintenance magnetic flow meter for any dirty liquid that is conductive or water based


KEF Series Electromagnetic Flow Meter

Description


Electromagnetic flow meter is a kind of induction instrument designed by Faraday’s law of
electromagnetic induction to measure flow of conductive media in the tube. It adopts the technology of
insertion of single chip to realize digital excitation and employs CAN local fieldbus.
Electromagnetic flow meter can realize local indication and output electrical current signal of 4-20mA
which can be used to record, adjust and control. Electromagnetic flow meters are widely used in
industrial sectors such as chemical industry, environmental protection, metallurgy, pharmaceutical, paper
making, water supply and removal etc.
Besides measuring flow of general conductive liquid electromagnetic flow meter can measure flow of
liquid-solid mixed fluid, high-viscosity fluid and salt, strong acid and strong alkali.

Features
1. Simple structures, firm, no movable parts and long operation life.(Guarantee in 1 years)
2. No intercepting fluid parts, no pressure loss and fluid clogging.
3. No mechanical inertia, quick response and good stability, application in automatic examination,
adjustment & controlling.
4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity,
density and pressure.
5. Employ Teflon or rubber liner and different combination of electrode material such as Hastelloy C,
Hastelloy B, 316L, and Titanium and adapt the need of different mediums.
6. Supply many styles of flow meters such as inline type and insertion type, etc.
Adopt EEPROM memory to measure operation data, safe and reliable protection of memory.
7. Integral type flow meters and remote type flow meters.
8. LCD back light display with high clearness. (Option: LED back light display)

Technical Data


Measuring system


Measuring principleFaraday’s law
Application rangeElectrically conductive fluids
Measured Value
Primary measured valueFlow velocity
Secondary measured valueVolume flow

Design



FeaturesFully welded maintenance-free sensor
Flange version with full bore flow tube
Standard as well as higher pressure ratings
Large diameter range from DN15~3000 with rugged liners approved for drinking water
Industry specific insertion lengths
Modular constructionThe measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version
Compact versionWith 511B converter: 110~240Vac Power
With 521B converter: 18~36V DC Power
With W800L/W800W: Battery Power
Remote version

In wall mount version with 211B converter

(110~240Vac or 221B converter 18~36V DC

With W800F converter: Battery Power
Measurement range-12…+12m/s /-40...+40ft/s

Measuring accuracy


Reference conditionsFlow conditions similar to EN 29104
Medium: water
Electrical conductivity: ≥300μs/cm
Temperature: +10~+30℃/+50~+80℉

Inlet setion: ≥5DN
Operating pressure: 1Bar/14.5psig
Flow Meter AccuracyStandard: 0.5% of rate
Optional: 0.2% of rate

Operating conditions


Temperature
Process temperatureHard rubber liner: -5~+60℃
Polypropylene liner: -5~+90℃
PTEF liner: -5~+120℃
Ambient temperatureStandard (with aluminum converter housing)

-20~+60℃ (Protect electrics against self-heating

with ambient temperature above 55℃

Stroage temperature-20~70℃
Pressure
EN 1092-1DN2200~3000: PN2.5
DN1200~2000: PN6
DN200~1000: PN10
DN65~150: PN16
DN10~50: PN40
Other pressure on request
ISO insertion lengthOptional for DN15~600
ASME B16.51~24”: 150lb RF
Other pressure on request
JISDN10~1000/ 2~40”: 10K
Other pressure on request
Pressure dropNegligible

Fluid
Physical conditionConductive liquids
Electrical conductivity≥5μs/cm
Permissible gas content (volume)≤5%
Permissible solid content≤70%

Installation conditions


InstallationTake care that flow sensor is always fully filled
For detailed information see chapter “Cautions for installation”
Flow directionForward and reverse
Arrow on flow sensor indicates positive flow direction
Inlet run≥5 DN
Outlet run≥2 DN

Process connection


Flange
EN1092-1DN25~3000 in PN6~40
ASME1~120” in 150 lb RF
JIS25~1000 in 10~20k
Design of gasket surfaceRF
Other sizes or pressure ratings on request

Ordering information


Model Suffix Code Description
GXEFM3000-1200-Com-4mA-Hart-DC-Pt-Teflon1-GR-D1400-Exd IIC T6 Gb 
Diameter-XXXX         Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
Transmitter-Com        Compact type
-Rem        Remote type
-Bat        Battery power supply type
-PRO        process control type
Signal Outpt-N       No output
-4mA       4-20mA
-Pul       1~5KHz pulse
-4Pul       4~20mA / 1~5KHz
Communication-N      No communication
-Hart      HART
-MOD      MODBUS-RTU
-PRO      PROFIBUS
-GPRS      GPRS net
-CDMA      CDMA net
-WHRT      Wireless HART
-Other      special order
Power Supply-AC     85V~250Vac@46~63Hz
nominal 20W
-DC     20~36VDC nominal 20W
-Bat     Battery power supply
-Bat+     Battery +12Vdc dual power supply
Other     special request
Electorde Material-316L    Stainless steel 316L
-HasB    Hastelloy B
-HasC    Hastelloy C276
-Pt    Platinum
-Ta    Tantalum
-Ti    Titanium
-WC    wolfram carbide
Liner material-Rub1   Neoprene(-20-60℃)
-Rub2   Neoprene(-20-90℃)
-Tef1   polytetrafluroethylene(-30-120℃)
-Tef2   polytetrafluroethylene(-20-160℃)
-P   Polyurethane
-FVMQ   FVMQ
-PFA   DFA
-ETFE   Ethylene tetraflurorethylene
Grounding Ring-N  No grounding ring
-GR  Grounding ring
-GE  Grounding Electrode
Wet part Connection attribute-DXX DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
-AX AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
-JX JX: J1, J2, J3 J1: JIS10K;
J2: JIS 20K; J3: JIS 30K
-WF Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
-TR Tri-Clamp for sanitary type (Body material: stainless steel)
Explosive-proof grade-Exd IIC T6 GbExd IIC T6 Gb
-Ndon't need

Application



China Intelligent Electromagnetic Flow Meter 20ma River Water Magnetic Nitric Acid supplier

Intelligent Electromagnetic Flow Meter 20ma River Water Magnetic Nitric Acid

Inquiry Cart 0