2000mg/L IP68 Protection Suspension Sensor Support RS-485

Brand Name:kacise
Certification:CE
Model Number:KSS601
Minimum Order Quantity:0-100
Delivery Time:3-10days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

KSS601 Online Suspension Sensor 90° Scattered Light Principle, Built-In Temperature Sensor Support RS-485, Modbus/RTU

1.Operational Principle

The KSS601 integrated online suspension sensor is designed and manufactured using the principle of scattered light suspension measurement. When a beam of light is incident on a water sample, the light is scattered by the suspended matter in the water sample, and the scattered light in the water sample is calculated by measuring the intensity of the scattered light perpendicular to the incident light and comparing it with the internal calibration value, linearized to output the final value.

2.Feature

  • 90° scattered light principle, built-in temperature sensor
  • Support RS-485, Modbus/RTU protocol
  • Fiber-optic structure, strong resistance to external light interference
  • Infrared LED light source with high stability
  • IP68 protection, water depth within 20 meters
  • Convenient, fast, stable and easy to maintain

3.Technical Specifications

ModelKSS601
Measuring principleScattered light method
Measuring range0~2000mg/L
Resolution0.1NTU,0.1℃
Precision±5%
Calibration methodTwo-point calibration
Temperature compensationAuto temperature compensation(Pt1000)
Output methodRS-485(Modbus/RTU)
Working conditions0~50℃,<0.2MPa
storage temperature-5~65℃
Installation methodImmersion mounting, 3/4 NPT thread
Cable length5 meters, other lengths can be customized
Power consumption<0.3W@12V
Power supply12~24VDC ±10%
Protection gradeIP68

4.Dimensional Drawing

5.Installation and Electrical Connection

5.1 Installation


Installation distance requirements: keep more than 5cm with the side wall and 10cm or more with the bottom.

5.2 Electrical Connection

a) Red line - power cord (12 ~ 24V)
b) Black line - ground (GND)

c) Blue line - 485A
d) white line - 485B
e) bare wire - shielded wire
After wiring is completed, it should be carefully checked to avoid incorrect connections before powering up.

Cable specification: Considering that the cable is immersed in water (including sea water) for a long time or exposed to the air, the cable has certain corrosion resistance. The outer diameter of the cable is Φ6 mm and all interfaces are waterproof.

6.Maintenance

6.1 Maintenance Procedures and Methods

6.1.1 Maintenance Schedule
The cleanliness of the measurement window is very important to maintain accurate readings.

Maintenance taskRecommended maintenance frequency
Calibrate the sensor (if required by the competent authority)According to the maintenance schedule required by the competent authority

6.1.2 Maintenance Methods

  • Sensor outer surface: Clean the outer surface of the sensor with tap water. If there is still debris left, wipe it with a soft, damp cloth. For some stubborn dirt, add some household washing liquid to the tap water to clean it.
  • Check the cable of the sensor: the cable should not be tight when working normally, otherwise the cable inside the cable will be broken and the sensor will not work properly.
  • Check the sensor's measurement window for dirt.

6.1.3 Notes
The probe contains sensitive optical and electronic components. Make sure the probe is not subject to severe mechanical shock. There are no parts inside the probe that require user maintenance.

6.2 Sensor Calibration

  • Zero calibration: use a large amount of beaker to take a proper amount of zero suspension or a known concentration of suspension (0 ~ 200.0mg / L), the sensor is placed vertically in the solution, the front end of the sensor is at least 10cm from the bottom of the beaker, 1 minute Zero calibration is performed after the value is stable. The instructions refer to the appendix.
  • Slope calibration: Place the sensor probe in a suspension of known concentration (200.0~2000.0mg/L). The front end of the sensor is at least 10cm away from the bottom of the beaker. After 1 minute, the value is stabilized and the slope is calibrated. The instructions refer to the appendix.

Note: No bubbles can be generated at the front of the probe.

6.3 Frequently Asked Questions

ProblemPossible reasonSolution
The operation interface cannot be connected or the measurement result is not displayed.Controller and cable connection errorReconnect controller and cable
Cable failurePlease contact us
The measured value is too high, too low or the value is continuously unstable.The sensor window is attached by a foreign objectCleaning the sensor window surface

7.Quality and Service

7.1 Quality Assurance

  • The quality inspection department has standardized inspection procedures, advanced and perfect testing equipment and means, and strictly in accordance with the regulations, to do 72-hour aging test and stability test on the product, and not to allow one unqualified product to leave the factory.
  • The receiving party directly returns the product batch with a failure rate of 2%, and all the costs incurred are borne by the supplier. The reference standard refers to the product description provided by the supplier.
  • Guarantee the quantity of goods and the speed of shipment.

7.2 Accessories and Spare Parts
This product includes:

  • 1 sensor
  • 1 copy of the instructions
  • 1 certificate

7.3 After-sales Service Commitment
The company provides local after-sales service within one year from the date of sale, but does not include damage caused by improper use. If repair or adjustment is required, please return it, but the shipping cost must be conceited. Damaged on the way, the company will repair the damage of the instrument for free.


Contact Us

Website www.kacise.com

Phone +86-17719566736

Email sales@kacise.com

Location Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China



China 2000mg/L IP68 Protection Suspension Sensor Support RS-485 supplier

2000mg/L IP68 Protection Suspension Sensor Support RS-485

Inquiry Cart 0