4000 NTU Lightning Proof 316L 0.6MPa Water Quality Sensor

Brand Name:kacise
Certification:CE,FDA
Model Number:KBU601
Minimum Order Quantity:0-100
Delivery Time:10-15 days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

KLT900 online Lightning proof enclosure turbidity meter 316L stainless steel sensor

Production Introduction


The optical method is often used to measure the turbidity of liquid by comparing with the standard turbidity.The turbidimeter uses the principle of 90° scattered light to accurately measure the turbidimetric value of the tested sample compared with the standard Turbidimetric solution of Formazin.

With its unique software function, the scattered light turbidimeter ensures the accuracy and reliable stability of the instrument.It is widely used in the determination of liquid turbidity in industrial and mining, medical treatment, environmental protection, food, brewing, textile, chemical and other departments.

The ratio of scattered light to transmitted light is taken to measure the turbidity of liquid.The tungsten lamp as light source, light through the lens and color filter, all the way through the measured turbidity liquid transmission to cell 1 received, the other all the way through the liquid 2 receive 90 °scattering to the cell, acoustic signal by the op-amp signal processing after A/D conversion, data processing by single chip microcomputer, through the keyboard control measurement showed that the liquid turbidity value and print output.


Measuring principle


TSS turbidity/suspended matter concentration meter work principle as shown in figure 1-1, sensor transmitter to send the red outside light in transit after being measured the absorption and scattering of content, part of the scattering light to 135°direction of detector, part of the scattering light detector to 90°direction.The light intensity in the direction of 135°and 90°is related to the turbidity of the measured sewage to a certain extent, and the TURBidity of TSS is precisely based on this principle for measurement.


Turbidity meter size structure diagram


host size



sensor size


Turbidity meter technical parameters


Performancevalue
SystemMenu-driven software, with multi-point calibration function and binding programming, can set the measurement range, relay and current output;
SupplyAC220V (min85V- max265V) 50/60Hz
Maximum power consumed15 VA
Fuse2A /220VAC
Range0~4000 NTU
Measurement UnitNTU and mg/L are available.
Resolution Rate0.1NTU
Accuracy2% of the measured value, within 10NTU the error is not greater than 1NTU.
DisplayThe display screen is 192 × 64 pixels, which can display turbidity measurement value, current time, historical trend line, etc.
Principleinfrared light scattering 90° and 135°
Output1 channel 4~20mA current signal isolation output, maximum load 750 ohms; 1-channel RS232 and 1-channel RS485 digital output (optional); 3 alarm signal relays, capacity 220 VAC/ 2 A, output can be set by the user;
Host:MaterialABS+PC
Host:Protection LevelIP65
Sensor Material316L stainless steel
Cable LengthDedicated shield cable, standard 10 meters (extendable)
Operating Temperature0-50℃
Pressure0.6MPa
CalibrateIt has been calibrated before delivery and no calibration is needed on site

Ordering Information Selection Table

Ordering Information Selection Table
KXTX00PH/ORP analyzer
Power supplyDC24V
AC220V
Cable length5m
10m
15m
20m
Temperature compensationSensor without temperature compensation
Sensor with temperature compensation
Signal outputOnly 4-20mA
Only 485
Also with 4-20mA , 485 signal output
Special custom signal
KLT500-DC24V--5m-Sensor without temperature compensation-Only 485Low Turbidity host, with DC 24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication.

Calibration

The standard turbidity liquid of 20NTU, 100NTU, 200NTU and 400NTU has been preliminarily calibrated before the delivery of the scattered light turbidimeter,to adjust the multi-section gain and store in EPROM. After the delivery of the turbidimeter, according to the turbidity liquid measured, the standard turbidity liquid is appropriately selected for accurate calibration:

(1) Sample <20NTU: 20NTU standard turbidity solution was selected;

(2) 20NTU< sample <100NTU: 100NUT standard turbidity solution was selected;

(3) 100NTU< sample under test <200NTU: 200NTU standard turbidity solution was selected;

(4) 200NTU< sample under test <400NTU: 400NTU standard turbidity solution was selected.


Contact us


Website: www.kacise.com
Phone: +86-17719566736
Email: sales@kacise.com
Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China



Abbreviations table
NTU
The unit of turbidity is "degree", which is equivalent to the degree of turbidity produced by 1L water containing 1mg SiO2 (or white clay, diatomite), which is 1 degree, or Jackson.Turbidity unit is JTU, 1JTU=1mg/L white clay suspension.
The turbidity shown by modern instruments is the unit of scattering turbidity NTU, also known as TU.1NTU= 1JTU.
Recently, it is considered internationally that the standard of turbidity prepared with ullotropin-hydrazine sulfate has good reproducibility and is chosen as the uniform standard of FTU.1FTU=1JTU.

China 4000 NTU Lightning Proof 316L 0.6MPa Water Quality Sensor supplier

4000 NTU Lightning Proof 316L 0.6MPa Water Quality Sensor

Inquiry Cart 0