Ip68 KPH500 PH Water Quality Sensor For Seawater with Protection Level ip68

Brand Name:kacise
Certification:CE,FDA
Model Number:KPH500
Minimum Order Quantity:0-100
Delivery Time:10-15 days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

KPH500 Ph Sensor Adapter PH Sensor For Seawater Water QualityPh Meter


Introduction

The PH/ORP meter is a high - precision instrument employed for detecting the pH and oxidation - reduction potential of liquids. It is constructed around a microcomputer, operating on the principle of the primary battery. This design makes it straightforward to operate and convenient to maintain. Unaffected by factors like color, turbidity, colloidal substances, oxidants, and reducing agents, it is applicable for the determination of diverse media, including clean water, wastewater, industrial water, and chemical reagents. Consequently, it finds extensive use in agriculture, environmental protection, and the industrial sector.


The sensor incorporates a composite electrode, which effectively mitigates the impact of the inconsistent "K" value. This enables long - term, stable, and accurate pH measurement. The internal structure of the sensor is depicted on the right.


Principle of measurement

PH meter is a potentiometric method to measure the PH of a solution, so the PH meter works in such a way that, in addition to measuring the PH of a solution, it can also measure the electromotive force of a battery.
The PH is the activity of hydrogen ions in a substance, and the PH is the negative of the logarithm of the concentration of hydrogen ions.The main measuring components of PH meter are glass electrode and reference electrode. Glass electrode is sensitive to PH and reference electrode has stable potential.If you put these two electrodes of the PH meter together in the same solution, you make a galvanic cell, and the potential of this galvanic cell is the algebraic sum of the potential of the glass electrode and the reference electrode.
The reference electrode potential of PH meter is stable, so in the case of temperature remains stable, the potential change of the galvanic cell composed of the solution and the electrode is only related to the potential of the glass electrode, and the potential of the glass electrode depends on the PH value of the solution to be measured, so through the measurement of the potential change, the PH value of the solution can be obtained.


Features

1. LCD display, Chinese menu operation, stable performance and strong reliability

2. High-performance operational amplifier, ORP positive and negative poles are symmetrical, small drift, high accuracy

3. Data is not lost after power off

4. Dual 4-20mA transmission output, relay high and low alarm control output, RS485 communication Output

5. Simultaneous display of PH value, temperature value, output current value, high alarm value, low alarm value


PH/ORP size structure chart

Host size

Sensor size



PH/ORP technical parameters

ClassPerformancePH parameterOPR parameter
HostMeasuring range0-14PH-2000mv-2000mv
Resolution0.01PH1mv
Precision2% Calibration accuracy
Operating TemperatureTransmitter 0-65℃
MaterialPVC
Protection LevelI65/IP67(customized version)
Signal Output

485 communication/4-20mA analog output/support HART protocol/NB.GPRS.LORA

Communication (function option)

Supply VoltageAC220V or DC24V (choose one of the two)
Power Consumption<1W
DisplayLCD Chinese display/TFT color LCD (customized version)
Installation MethodWall mount
SensorTemperature CompensationAutomatic temperature compensation
Protection Levelip68
Temperature0-60℃
Sensor MaterialPVC
Cable LengthDedicated PH cable, standard 5 meters (extendable)
Operating Temperature0-60℃
Storage Temperature-10-60℃
Installation MethodBracket drop-in installation

Ordering Information Selection Table
KPH500PH/ORP analyzer
Power supplyDC24V
AC220V
Cable length5m
10m
15m
20m
Temperature compensationSensor without temperature compensation
Sensor with temperature compensation
Signal outputOnly 4-20mA
Only 485
Also with 4-20mA , 485 signal output
Special custom signal
KPH500-P-DC24V-5m-Sensor without temperature compensation-Only 485PH host, with DC24V adapter, cable between host and sensor,The cable length is 5 meters, the sensor is equipped without temperature compensation, and is only 485 communication.
KPH500-R-AC220V-10m-Sensor with temperature compensation-Only 485

Optional ORP host, with 220V adapter, line between host and sensor

The cable length is 10 meters, the sensor with temperature compensation, and is equipped with only 485 communication signal output.


Contact us

Website: https://kcsensor.com/

Phone: +86-17719566736

Email: sales@kacise.com

Location: Tangyan South Road, High-tech Zone, Xi'an City, Shaanxi Province, China


China Ip68 KPH500 PH Water Quality Sensor For Seawater with Protection Level ip68 supplier