China Categories
English
Home /Plastic & Rubber Machinery /

Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage

Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage

Brand Name:Kacise
Certification:certificate of explosion-proof,
Model Number:M18 KUS1000
Minimum Order Quantity:0-100
Delivery Time:5-8 work days
Payment Terms:T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

40KHZ Frequency Ultrasonic Distance level Sensor 50mm - 1000mm Detection Range

1. Parameter

General specifications

Sensing range100... 1000 mm
Adjustment range
Unusable area0 ... 100 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox.220 kHz
Response delayapprox. 50 ms

Indicators/operating means

LED bluepower-on

LED yellow

indication of the switching state

flashing: program function object detected


LED red

permanently red: Error Red,flashing:program function,object not detected

Electrical specifications

Operating voltage UB15 ... 30 V DC , ripple 10 %SS
No-load supply current I0≤ 45 mA

Input

Input type1 TEACH-IN input

operating range A1: -UB ... +1 V, operating range A2: +6 V ...

+UB

input impedance: > 4.7 kΩ ; TEACH-IN program pulse: ≥ 1 s

Output

Output type1 switch output E4, NPN NO/NC,programmable
Rated operating current Ie200 mA , short-circuit/overload protected
Default settingSwitching point A1:70mm Switching point A2: 800mm
Voltage drop≤ 2.5 V
Repeat accuracy≤1 %
Switching frequency f≤ 13 Hz
Range hysteresis H2 % of the set operating distance
Temperature influence±1.5% of full-scale value

Ambient conditions

Ambient temperature-25…70℃(248...343K)
Storage temperature-40…85℃(233...358K)

Mechanical specifications

ConnectionV1 connector(M12×1),4-pin
Protection degreeIP67
Material Housingbrass, nickel-plated
Transducer

epoxy resin/hollow glass sphere mixture;

foam polyurethane, cover PBT

2. Dimensions

3. Electronic interface and signals definition


4. Description of Sensor Functions

Adjust the paramater

 The ultrasonic sensor features a switch output with two teachable
switching points. These are set by applying the supply voltage - UB
or + UB to the TEACH-IN input. The supply voltage must be applied
to the TEACH-IN input for at least 1 s.LEDs indicate whether the
sensor has recognised the target during the TEACH-IN procedure.
Switching point A1 is taught with - UB,A2 with +UB. Eight different
output functions can be set. Switching point, Setting distance only after power on. The internal
clock can assure can't be changed after 5 mins when power on. If
want to change the switching point, the user can only setting the
request distance after power restart.

TEACH-IN window mode, normally-open function

-Set target to near switching point

-TEACH-IN switching point A1 with - UB

-Set target to far switching point

-TEACH-IN switching point A2 with + UB

TEACH-IN window mode, normally-closed function

-Set target to far switching point

-TEACH-IN switching point A2 with - UB

-Set target to near switching point

-TEACH-IN switching point A1 with + UB

TEACH-IN switching point, normally-open function

-Set target to near switching point

-TEACH-IN switching point A1 with - UB

-Cover sensor with hand or remove all objects

from sensing range

-TEACH-IN switching point A2 with + UB

TEACH-IN switching point, normally-closed function

-Cover sensor with hand or remove all

objects from sensing range

-TEACH-IN switching point A2 with - UB

-Set target to near switching point

-TEACH-IN switching point A1 with + UB

TEAC-IN large hysteresis interval, normally-open mode

-Set target to near switching point

-TEACH-IN switching point A1 with + UB

-Set target to far switching point

-TEACH-IN switching point A2 with - UB

TEAC-IN large hysteresis interval, normally-closed mode

-Set target to far switching point

-TEACH-IN switching point A2 with + UB

-Set target to near switching point

-TEACH-IN switching point A1 with - UB

TEACH-IN detection of objects presence normally open mode

-Cover sensor with hand or remove all objects from

sensing range

-TEACH-IN switching point A2 with - UB

-Cover sensor with hand or remove all objects from

sensing range

-TEACH-IN switching point A2 with + UB

TEACH-IN detection of objects presence normally closed mode

-Cover sensor with hand or remove all objects from sensing range

-TEACH-IN switching point A2 with +UB

-Cover sensor with hand or remove all objects from sensing range

-TEACH-IN switching point A2 with -UB

Default setting of switching point

A1=blind range,A2=nominal distance


LED displays
Displays in dependence on operating modeRed LEDYellow LED

TEACH-IN switching point

Object detected

No object detected

Object uncertain(TEACH-IN invalid)


off flashes On


flashes off

off

Normal operationoffSwitching state
FaultonPrevious state

5. Installation conditions

If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.


China Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage supplier

Precision Long Range Distance Sensor 40KHZ Frequency 24VDC Operating Voltage