Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids

Brand Name:Kacise
Certification:certificate of explosion-proof, CE
Model Number:GXEFM2000
Minimum Order Quantity:1pcs
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, T/T, D/P, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

Kacise GXEFM2000 High accuracy clamp on industrial water flow meter transducer for flow test electromagnetic flow meter


Description


1. Simple structures, firm, no movable parts and long operation life.(Guarantee in 1 years)

2. No intercepting fluid parts, no pressure loss and fluid clogging.

3. No mechanical inertia, quick response and good stability, application in automatic examination, adjustment & controlling.

4. Measuring accuracy not influenced by physical parameters such as style, temperature, viscosity, density and pressure.


Parameters


Pipe diameterDN6~DN2600
Accuracy0.3% (Option), 0.5%, 1.0% of F.S..
RepeatabilityBelow 0.25%
PowerAC: 220V, 50-60Hz; DC: +24V(Option)
Output Signals4~20mA, Pulse, 0~5V
Conduit connectionM20 * 1.5 Thread
Communication InterfaceRS-232; RS-485; HART
Operation Pressure1.0MPa, 1.6MPa, 4.0MPa, 16MPa (Special)
Fluid Temperature-20°C~80°C, 80°C ~130°C, 130°C ~180°C Depending on Lining Material
Ambient TemperatureSensor -40°C ~80°C. transducer -15°C ~50°C
Ambient Humidity≤ 85%RH (at 20C)
Cable Outlet SizeM20×1.5
Power Supply220VAC±10%, 50-60Hz±1Hz, 24VDC±10%, Battery power (3-5years)
Power Consumption≤ 15W
Protection RatingsRemote type: sensor IP68, transducer IP65.
MaterialsElectrode316L (stainless steel), Hastelloy C, Hastelloy B,Titanium, Tantalum, etc.
LinerPTFE, Soft rubb er, Hard rubber, F46, FS, PUR.
Measuring tubeSS 304, carbon steel
FlangeCarbon Steal, SS304
Ground ring316L (stainless steel), HC, Ti, Ta, Cu.
Connection of Flange

National Standard GB9119-88 (DIN2051, BS4504), JIS,ANSI. Screw.

Tri-clamp for sanitary application

Insertion type.

EX-proof protectionExde ib ii BT2
Quality control

ISO9001-2008, CE


Measuring system


Measuring principleFaraday’s law
Application rangeElectrically conductive fluids
Measured Value
Primary measured valueFlow velocity
Secondary measured valueVolume flow

Design


FeaturesFully welded maintenance-free sensor
Flange version with full bore flow tube
Standard as well as higher pressure ratings
Large diameter range from DN15~3000 with rugged liners approved for drinking water
Industry specific insertion lengths
Modular constructionThe measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version
Compact versionWith 511B converter: 110~240Vac Power
With 521B converter: 18~36V DC Power
With W800L/W800W: Battery Power
Remote version

In wall mount version with 211B converter

(110~240Vac or 221B converter 18~36V DC

With W800F converter: Battery Power
Measurement range-12…+12m/s /-40...+40ft/s

Measuring accuracy


Reference conditionsFlow conditions similar to EN 29104
Medium: water
Electrical conductivity: ≥300μs/cm
Temperature: +10~+30℃/+50~+80℉

Inlet setion: ≥5DN
Operating pressure: 1Bar/14.5psig
Flow Meter AccuracyStandard: 0.5% of rate
Optional: 0.2% of rate

Operating conditions


Temperature
Process temperatureHard rubber liner: -5~+60℃
Polypropylene liner: -5~+90℃
PTEF liner: -5~+120℃
Ambient temperatureStandard (with aluminum converter housing)

-20~+60℃ (Protect electrics against self-heating

with ambient temperature above 55℃

Stroage temperature-20~70℃
Pressure
EN 1092-1DN2200~3000: PN2.5
DN1200~2000: PN6
DN200~1000: PN10
DN65~150: PN16
DN10~50: PN40
Other pressure on request
ISO insertion lengthOptional for DN15~600
ASME B16.51~24”: 150lb RF
Other pressure on request
JISDN10~1000/ 2~40”: 10K
Other pressure on request
Pressure dropNegligible

Fluid
Physical conditionConductive liquids
Electrical conductivity≥5μs/cm
Permissible gas content (volume)≤5%
Permissible solid content≤70%

Installation conditions


InstallationTake care that flow sensor is always fully filled
For detailed information see chapter “Cautions for installation”
Flow directionForward and reverse
Arrow on flow sensor indicates positive flow direction
Inlet run≥5 DN
Outlet run≥2 DN

Process connection


Flange
EN1092-1DN25~3000 in PN6~40
ASME1~120” in 150 lb RF
JIS25~1000 in 10~20k
Design of gasket surfaceRF
Other sizes or pressure ratings on request

Company Information

Xi'an Kacise is qualified with ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof certificates, etc. which ensure that our products comply with international standards.

We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. Based on experienced technical and management personnel, through efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider. And we are continuously trying to improve product quality.

Currently, Kacise sensors have already been exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing. We regard “reasonable prices, efficient production time and good after-sales service” as our tenet, and hope to cooperate with more customers for mutual development.

China Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids supplier

Large Diameter Range Electromagnetic Flow Meter For Electrically Conductive Fluids

Inquiry Cart 0