KUS550 ultrasonic level meter Range: 3m Output RS485 and Analog Output Low Power

Brand Name:Kacise
Certification:certificate of explosion-proof,
Model Number:KUS550
Minimum Order Quantity:0-100
Delivery Time:5-8 work days
Payment Terms:T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details
KUS550 Ultrasonic Level meter Range: 3m Output RS485 and Analog Output Low Power IP68 Grade
Introduction

The KUS550 Ultrasonic Level meter is a top-notch device. It has a range of 3m, allowing for effective level sensing. With both RS485 and Analog Outputs, it offers versatile connectivity options. Its low power consumption and IP68 grade make it suitable for various environments. Ideal for applications where accurate and reliable level detection is crucial.

Features

. Designed for outdoor or indoor environments

. High sensitivity

. Readings can occur up to every 50mS (20Hz) within 2meters

. Free run operation can continually measure and output ranger information

. 13-30 supply with very low average current draw

. 0-10V with RS485 interface.

. Sensor operates at 125KHz.

. Sensor beam angle is 7 degrees.

.The analogue output can be set between 0-10V can work with the switch output.

Applications

  • Tank level measurement
  • Bin level measurement
  • Proximity zone detection
  • People detection
  • Robot ranging sensor
  • Autonomous navigation
  • Multi-sensors navigation
  • Distance measuring
  • Long range object detection
  • Industrial automation

Parameters

General specifications


Model: KUS550
Measuring range

0.25m~3m (5m customizable)KUS550A

0.15m-0.6m(1m customizable)KUS550B;

Blind spotThe dead zone of KUS550A is 0 ... 250 mm (within 250mm is unstable working zone, it is not recommended to work in this range); the dead zone of KUS550B is 0-150mm;
Supply voltage3.3 ... 30 VDC, ripple 10 %SS
Working current≤ 45 mA (fastest measurement speed), typical power consumption ≤ 10 mA;
Output signal0-10V. 0-3V 0-5V /4-20mA/NPN/PNP/RS485 Analog output.
Measurement accuracy≤1 %F.S.
Temperature compensationYes
Ranging resolution0.1mm;

Working conditions

Working temperature-40…85℃ (233...358K)
Storage temperature-40…85℃ (233...358K)

Other instructions

Electrical connection5-core cable (analog output), 6-core cable (switch output) .
Protection classIP68
Shell materialPVC /PVDF/PTFE/ABS

Electronic interface and signals definition

Analogue output type wiring diagram

.


Switch output type wiring diagram


Dimensions

Ordering information

KUSModelOutputMax rangeDescription
550
Customized
SW-1Switch Output,SW-1 for one switch output,SW-2 for 2 switch outputs
mA3 wire 4-20mA output
10VOutput is Vout 0-10V
5VOutput is Vout 0-5V
3VOutput is Vout 0-3V
RS485Output is RS485
TTLUART TTL output
XX mXX m is the maxim range can be detected, the max range is 5 meters. Default is 2.5m