Home /

Milk Fruit Juice Electromagnetic Flow Meter Flow Testing Instrument GXEFM2000 Series

Milk Fruit Juice Electromagnetic Flow Meter Flow Testing Instrument GXEFM2000 Series

Brand Name:Kacise
Certification:certificate of explosion-proof, CE
Model Number:GXEFM2000
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, T/T, D/P, Western Union, MoneyGram
Place of Origin:China (Mainland)
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Milk Fruit Juice Flow Testing Instrument GXEFM2000 Series Electromagnetic Flow Meter

1. Description

GXEFM2000 series electromagnetic flow meters are intended for fluid measurement in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.

There are two basic components of electromagnetic flow meter.

The advantages of EFM2000 series electromagnetic flow meters are as follows.

1:No obstacle existed in the measuring tube, so the pressure loss is zero, hardly blocked.

2:The request of anticorrosion, wear resistance can be satisfied, if the proper electrodes and lining material are adopt.

3:The measuring results have no relation with the physical parameters of liquid, such as pressure, temperature. Density viscosity, conductivity rate, etc. It is not influenced by the circumstances, so the accuracy is high, working process is stable and reliable.

4: Adopt the dual row flow indicator of back lighted dot array, display the instantaneous and accumulative volume, simultaneously, also displays the working status, parameters, measuring units, etc.

5: The measuring range is available of this flow meter is wide, lt's range rate normally is 20:1, generally can reach 150:1.

6: This flow meter has multi-type outputs, can be matched with computer, combined instrument unit, can meet the requirements of printing, communication and networking.

2. Technical Data


Measuring system

Measuring principle

Faraday’s law


Application rangeElectrically conductive fluids
Measured Value
Primary measured valueFlow velocity
Secondary measured valueVolume flow
Flow range

0.15... 15m/s ;

0.02...+40ft/s

Flow medium attribution

Electrical conductivity: ≥5μs/cm

Medium temperature range -20 to 392˚F(-29 to 200˚C) Transient 480 ˚F(250 ˚C)

Almost all kinds of acid alkali liquid


Transmitter Selection

260E is a split type electromagnetic Transmitter. 260D and 260A are compact type transmitter.

TransmitterGeneral characteristics
Infrared handing telecontrol keyboard,all the functions of far-untouched controlling converter.
HART/Analog and Pulse outputs available, Modbus-RTU RS-485 and Pulse output available, Profibus-DP available
Alarm OC outputs available, Empty pipe flow rate abnormal alarm available
Recording time when power turn-off, to record power broken time of instrument system automatically and recruit to count the missing flux;Recording function of hour gross, to record the flux gross by hour, fit for timed measure;
Multi language panel available.


Infrared handing telecontrol keyboard,all the functions of far-untouched controlling converter.
Both 85V--250VAC and16V--36VDC;power supply available
Multi language panel available
Recording function of hour gross, to record the flux gross by hour, fit for timed measure;
GPRS wireless communication available with battery power supply
Multi language panel available.


support multi sensors for 1 transmitter
special for process control industry application
Multi language panel available.

Sensor type

The pipe diameter of sensor is available from 15mm to 3000mm. choose the proper pipe diameter and size of the application field.





Norminal Diamter (mm)Max Process Pressure MPa*LDD0Hhn-Ø
104.015090602201024-Ø14
1515095652221064-Ø14
20150105752301104-Ø14
25150115852351154-Ø14
321501401002551224-Ø18
401501501102601274-Ø18
502001651252701404-Ø18
652001851452751488-Ø18
802002001602801548-Ø18
1001.62502201802901638-Ø18
1252502502103201758-Ø18
1503002852403302008-Ø22
2001.03503402953402208-Ø22
25040039535036024012-Ø22
30050044540040528512-Ø22
3505005054604403016-Ø22
40060056551547035016-Ø26
45060061556550038020-Ø26
50060067062053041020-Ø26
60060078072559047020-Ø30
70070089584065053024-Ø30
800800101595072060024-Ø33
9009001115105077065028-Ø33
100010001405116083070028-Ø36
12000.612001405134095080032-Ø33
1400140016301560105090036-Ø36
16001600183017601150100040-Ø36
18001800204019701250110044-Ø39
20002000226521801350120048-Ø42
22000.252200240523401450130052-Ø33

* higher pressure can be specially ordered, there are no product in storage.


Liner Material Selection


LinerNotesTemp limitsType and Line size
NeopreneTypically applied to water and sea water. Abrasion resistant to slurries with small particles.

0 to 185˚F

(-18 to 85˚C)

DN 50 - 2000

2 - 80 inch

PolyurethaneTypically applied to slurry (no chemicals). Abrasion resistant to slurries with small particles. special for slurry and chemical slurry

0 to 140˚F

(-18 to 60˚C)

DN15 - 900

0.5 - 36 inch

FVMQTypically for high temperature waters, Abrasive resistance, but anti-corrosiveness performance not well

0 to 392˚F

(-18 to 200˚C)

Transient 250 ˚C

DN50-1200

2-50inch

F4(PTFE)

BETTER FLUOROPOLYMER

More cost effective than PFA. Excellent chemical resistance, but less abrasion resistance than PFA.

-20 to 350˚F

(-29 to 177˚C)

DN10 -1600

0.4 -63inch

PFA

BEST FLUOROPOLYMER

Excellent resistance to chemicals and abrasion. Suitable for any application.

-20 to 350˚F

(-29 to 177˚C)

DN10 – 400

0.4-16 inch

ETFE

GOOD FLUOROPOLYMER

Similar chemical and abrasion resistance to PTFE, but a lower maxium temperature and more expensive.

-20 to 300˚F

(-29 to 149˚C)

Flanged 15–3000mm

0.5 - 115 inch

Wafer 15 - 200mm

0.5 - 8inch


Electrode Material Selection


MaterialApplication Description
316LSSTStandard electrode material. Compatible with most low concentration water based applications. Avoid using stainless in higher concentration acid applications. Such as municipal water supply, Industrial water supply, groundwater process, weak corrosive chemical fluid
Hastelloy BIdeal for hydrochloric acid(concentration lower than10% v/v),phosphate, organic acids, sodium hydroxide.
Hastelloy C276Use in medium to high concentration acids where SST is not acceptable. Use in applications with high chloride concentrations, such as sea water,
PlatinumIdeal for liquor applications found in pulp and paper industry. Also ideal as a spare electrode option to cover nearly every application in a plant. Compatible with nearly every process fluid.
TantalumIdeal for high concentration acid flows such as hydrochloric and hydrofluoric acids.
TitaniumIdeal for high concentration caustic (base) applications such as sodium and potassium hydroxides.
wolfram carbide

Ideal for paper pulp, sewage some kind of slurry with micro particles;

Not proper for Inorganic acid, Organic acids, oxide fulid.

Ask for suggestion before ordering about the Electrode Material needed


1. Ordering information


Model Suffix Code Description
GXEFM2000-1200-Com-4mA-Hart-DC-Pt-Teflon1-GR-D1400-Exd IIC T6 Gb 
Diameter-XXXX         Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
Transmitter-Com        Compact type
-Rem        Remote type
-Bat        Battery power supply type
-PRO        process control type
Signal Outpt-N       No output
-4mA       4-20mA
-Pul       1~5KHz pulse
-4Pul       4~20mA / 1~5KHz
Communication-N      No communication
-Hart      HART
-MOD      MODBUS-RTU
-PRO      PROFIBUS
-GPRS      GPRS net
-CDMA      CDMA net
-WHRT      Wireless HART
-Other      special order
Power Supply-AC     85V~250Vac@46~63Hz
nominal 20W
-DC     20~36VDC nominal 20W
-Bat     Battery power supply
-Bat+     Battery +12Vdc dual power supply
Other     special request
Electorde Material-316L    Stainless steel 316L
-HasB    Hastelloy B
-HasC    Hastelloy C276
-Pt    Platinum
-Ta    Tantalum
-Ti    Titanium
-WC    wolfram carbide
Liner material-Rub1   Neoprene(-20-60℃)
-Rub2   Neoprene(-20-90℃)
-Tef1   polytetrafluroethylene(-30-120℃)
-Tef2   polytetrafluroethylene(-20-160℃)
-P   Polyurethane
-FVMQ   FVMQ
-PFA   DFA
-ETFE   Ethylene tetraflurorethylene
Grounding Ring-N  No grounding ring
-GR  Grounding ring
-GE  Grounding Electrode
Wet part Connection attribute-DXX DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
-AX AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
-JX JX: J1, J2, J3 J1: JIS10K;
J2: JIS 20K; J3: JIS 30K
-WF Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
-TR Tri-Clamp for sanitary type (Body material: stainless steel)
Explosive-proof grade-Exd IIC T6 GbExd IIC T6 Gb
-Ndon't need

China Milk Fruit Juice Electromagnetic Flow Meter Flow Testing Instrument GXEFM2000 Series supplier

Milk Fruit Juice Electromagnetic Flow Meter Flow Testing Instrument GXEFM2000 Series

Inquiry Cart 0