Absolute pressure transmitter for atmospheric measurement of explosion-proof DC and AC voltage output CE

Brand Name:Kacise
Certification:Intrinsically safe mode E, Isolation explosion proof D, CE
Model Number:GXPS700
Minimum Order Quantity:1 Piece/pieces
Delivery Time:5-8 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

GXPS700 Anti-explosion DC and AC Voltage Output Absolute pressure transmitter With CE for Atmosphere measure

Application

  • Atmosphere measure
  • Aviation, spaceflight, navigation
  • Packaging machinery
  • Petrochemical industry
  • Meteorological monitoring
  • Automatic detection system
  • The mine wind pressure test
  • Top floor apartment management

Feature

  • Accuracy: ±0.25, ±0.5%F.S
  • Various of measuring range and signal output
  • Various of connector and pressure port
  • Non polarity two wire current output
  • DC and AC voltage output
  • Intrinsically safe mode, isolation explosion proof,
  • CE certificate, RoHS compliant

Introduction


GXPS700 Series absolute pressure transmitter is in an absolute vacuum as a reference point for pressure measuring. Connector size and structure size covers all products produced by our company structure and output interface.

  1. Atmospheric pressure: The thick atmosphere surrounded by the surface of the earth which the pressure generated by the objects on the Earth's surface or the surface is called the atmospheric pressure, code name: B
  2. Gauge pressure=relative pressure, Atmospheric pressure as zero resultant pressure value called gauge pressure or relative pressure, code name: Pg
  3. Absolute pressure: Absolute zero pressure (absolute vacuum) for zero resultant pressure value called absolute pressure, code name: PABS
  4. Absolute pressure=relative pressure+ atmospheric pressure, PABS=Pg+ B
  5. Vacuum = atmospheric pressure - absolute pressure Kv =B-PABS.(B>PABS)

Electronic interface and signals definition


Parameter


Spec.Value
Pressure range0~0.01MPa......40MPa
Load pressure1.5times nominal value pressure (1.5X)
Rupture pressure3times nominal value pressure (3X)
Accuracy±0.25%F.S, ±0.5%F.S
StabilityTypical value 0.25%F.S, Max. value: 0.4%F.S
Operating temperature-40°C~85°C
Compensation temperature-10°C~70°C
Medium compatibilityAll Caustic Medium Compatible with 1Cr18Ni9Ti
Electrical performance2 wire system3 wire system
Output signal4~20mA0~5V0~10V
Power supply10~30Vdc6~24Vdc/10~36Vac11~30Vdc/20~36Vac
Load pressure(U-10)/0.02(Ω)〉100kΩ
Insulation>100M Ω@50V
Electrical connectionConnector DIN43650, IP65
Air plug GX16-7, IP45
Waterproof outlet, IP68
Pressure portM20×1.5, G1/2, G1/4, NPT1/4, NPT1/2
Response time10ms
CertificateIntrinsically safe mode E, Isolation explosion proof D, CE
EMI/EMCEMI: EN50081-1/-2; EMC: EN50082-2

Company Information

Xi'an Kacise is qualified with ISO 9001-2008, GJB 9001B-2009, CE, intrinsic safety explosion-proof and isolated safety explosion-proof certificates, etc. which ensure that our products comply with international standards.

We have been specializing in manufacturing pressure, level and flow measuring instruments and related products for 10 years. Based on experienced technical and management personnel, through efforts of our entire staff, we have become a professional measuring instrument manufacturer and solution provider. And we are continuously trying to improve product quality.

Currently, Kacise sensors have already been exported to America, Spain, Australia, Chile and 20 other countries and regions, and received many favorable feedbacks. Our overseas distributers are also increasing. We regard “reasonable prices, efficient production time and good after-sales service” as our tenet, and hope to cooperate with more customers for mutual development.

China Absolute pressure transmitter for atmospheric measurement of explosion-proof DC and AC voltage output  CE supplier

Absolute pressure transmitter for atmospheric measurement of explosion-proof DC and AC voltage output CE

Inquiry Cart 0